FORT WORTH, TX —
OSHA Inspection: UMC ENERGY SOLUTIONS
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of UMC ENERGY SOLUTIONS in 3201 N. SYLVANIA BLDG. 601, FORT WORTH, TX 76111 (NAICS 213112). OSHA activity number 345279319.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UMC ENERGY SOLUTIONS
- Site address
- 3201 N. SYLVANIA BLDG. 601
- City
- FORT WORTH
- State
- TX
- ZIP
- 76111
- Mailing
- 3201 N. SYLVANIA BLDG. 601, FORT WORTH, TX 76111
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 87
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- May 27, 2021
- Penalty
- Initial $7,510 · Current $4,506 Reduced
General-duty citation text
29 CFR OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crush-by hazards: On or about April 27, 2021, and times prior thereto, employees operated a Toyota forklift without wearing a seatbelt.
Recent events (2)
- — I (S) $4506
- — Z (S) $7510
1910.37 B02
- Issued
- May 27, 2021
- Penalty
- Initial $3,481 · Current $2,089 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit". On or about April 27, 2021 and at times prior thereto, on the west side of the shop, the employer did not ensure the exit door was equipped with a serviceable "EXIT" sign exposing employees to entrapment hazards.
Recent events (2)
- — I (S) $2088.6
- — Z (S) $3481
1910.178 Q01
- Issued
- May 27, 2021
- Penalty
- Initial $3,481 · Current $2,089 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: On or about April 27, 2021, and times prior thereto, employer did not ensure that a Toyota forklift, was taken out of service and/or repairs were not made by authorized personnel, exposing employees to possible struck by hazards.
Recent events (2)
- — I (S) $2088.6
- — Z (S) $3481
1910.178 L01 I
- Issued
- May 27, 2021
- Abate by
- Jun 25, 2021
- Penalty
- Initial $2,731 · Current $1,639 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): At this establishment, the employer had not ensured that each authorized powered industrial truck operator is competent to operate the powered industrial trucks safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l) of 1910.178. On or about April 27, 2021, and times prior thereto, the employer did not ensure employees operating power industrial forklifts were trained and certified, exposing employees to struck-by hazards. UMC Energy Solutions was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.178(l)(1)(i) which was contained in OSHA inspection number 1354480, citation number 01, item number 004 and was affirmed as a final order on May 1, 2019, with respect to a workplace located at 3201 N Sylvania, Fort Worth, Texas 76111.
Recent events (2)
- — I (R) $1638.6
- — Z (R) $2731
1910.178 Q07
- Issued
- May 27, 2021
- Abate by
- Jun 25, 2021
- Penalty
- Initial $2,731 · Current $1,639 Reduced
General-duty citation text
29 CFR 1910.178(q)(7):Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift. On or about April 27, 2021, and times prior thereto, the employer did not ensured that a power industrial truck was not placed back into operations after defects were found including, but not limited to horn not working, seat belt being broken and back up alarm not working, exposing employees to struck-by hazards. UMC Energy Solutions was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.178(q)(7) which was contained in OSHA inspection number 1354480, citation number 01, item number 005 and was affirmed as a final order on May 1, 2019, with respect to a workplace located at 3201 N Sylvania, Fort Worth, Texas 76111.
Recent events (2)
- — I (R) $1638.6
- — Z (R) $2731
1910.37 A03
- Issued
- May 27, 2021
- Penalty
- Initial $767 · Current $460 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On the west side of the shop, the path to the west exit door was blocked by steel material exposing employees to entrapment and fire hazards.
Recent events (2)
- — I (O) $460.2
- — Z (O) $767
More inspections at UMC Energy Solutions
View UMC Energy Solutions's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345279319.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.