LANCASTER, NY —
OSHA Inspection: PCB PIEZOTRONICS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PCB PIEZOTRONICS, INC. in 4355 WALDEN AVENUE, LANCASTER, NY 14086 (NAICS 334419). OSHA activity number 345281117.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCB PIEZOTRONICS, INC.
- Site address
- 4355 WALDEN AVENUE
- City
- LANCASTER
- State
- NY
- ZIP
- 14086
- Mailing
- 3425 WALDEN AVENUE, BUFFALO, NY 14043
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334419
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1025 C01
- Issued
- Sep 24, 2021
- Abate by
- Jan 28, 2022
- Penalty
- Initial $9,753 · Current $5,900 Reduced
1591
General-duty citation text
29 CFR 1910.1025(c)(1):Employee(s) were exposed to lead at concentrations greater than fifty micrograms per cubic meter of air averaged over an eight-hour period: a) Lead Powder Room - On or about 8/4/21, a Crystals Technician, working in the Powder Mixing Station, was exposed to lead at an 8 hour time-weighted average (TWA) concentration of approximately 141.8 ug/m3 during the 377 minute sampling period; a zero exposure was calculated for the 103 minutes not sampled. This level is approximately 2.8 times the permissible exposure limit (PEL) of 50 ug/m3. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5900
- — Z (S) $9753
1910.1025 E01 I
- Issued
- Sep 24, 2021
- Abate by
- Jan 28, 2022
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1910.1025(e)(1)(i):For any employees exposed to lead above the permissible exposure limit for more than 30 days per year the employer did not implement engineering and work practice controls (including administrative controls) to reduce and maintain employee exposure to lead : a) Lead Powder Room - On or about 8/4/21, a Crystals Technician, working in the Powder Mixing Station, was exposed to lead at an 8 hour time-weighted average (TWA) concentration of approximately 141.8 ug/m3 during the 377 minute sampling period; a zero exposure was calculated for the 103 minutes not sampled. This level is approximately 2.8 times the permissible exposure limit (PEL) of 50 ug/m3. The employer did not implement engineering controls that effectively reduced employee exposures below the permissible exposure limit for lead.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at PCB Piezotronics, INC.
View PCB Piezotronics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334419)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345281117.