DEPEW, NY —
OSHA Inspection: PCB PIEZOTRONICS INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PCB PIEZOTRONICS INC in 3395 WALDEN AVENUE, DEPEW, NY 14043 (NAICS 334516). OSHA activity number 345814792.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCB PIEZOTRONICS INC
- Site address
- 3395 WALDEN AVENUE
- City
- DEPEW
- State
- NY
- ZIP
- 14043
- Mailing
- 3425 WALDEN AVENUE, DEPEW, NY 14043
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334516
- Employees
- 150
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Mar 7, 2022
- Abate by
- Apr 19, 2022
- Penalty
- Initial $10,360 · Current $7,770 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by shear points: a) On or about 03/02/2022 in the precision machining center; where employees were exposed to a shear point created by the clamp and the frame of the Cosen horizontal band saw. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $7770
- — Z (S) $10360
1910.147 C06 I C
- Issued
- Mar 7, 2022
- Abate by
- Apr 19, 2022
- Penalty
- Initial $4,661 · Current $3,496 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the employer did not conduct a periodic inspection, at least annually, which included a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 03/03/2022 throughout establishment; where employee perform covered operations such as, but not limited to, changing saw blades, changing belts and other servicing/maintenance on machines and equipment. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3495.75
- — Z (S) $4661
More inspections at PCB Piezotronics INC
View PCB Piezotronics INC's full OSHA safety record →
More inspections in this industry (NAICS 334516)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345814792.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.