Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPT OF INTERIOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT OF INTERIOR in 214 PARKWAY MAINTENANCE ROAD, SPRUCE PINE, NC 28777 (NAICS 712190). OSHA activity number 345291884.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept of Interior — free Get an email when a new federal OSHA severe-injury report for U.S. Dept of Interior is published. One employer, no account, unsubscribe in one click.
Site address
214 PARKWAY MAINTENANCE ROAD
City
SPRUCE PINE
State
NC
ZIP
28777
Mailing
199 HEMPHILL KNOB RD, ASHEVILLE, NC 28803
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
150
Ownership type
D

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(3)(ii):The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefore, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  On or before May 4, 2021, overhead door was not guarded to prevent body parts in the danger zone during the doors operating cycle.
Recent events (1)
  • — Z (S) $0

1910.305 B01 I

Serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(i):Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.  On or about May 3, 2021, employees were exposed to electrical hazards, from a breaker panel that had 2 open knockouts, exposing live electrical parts.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 7, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made.    On or before May 4, 2021, the employer did not remove a damaged battery charger flexible cord from service.
Recent events (1)
  • — Z (S) $0

View U.S. Dept of Interior's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345291884.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.