NEW BRAUNFELS, TX —
OSHA Inspection: CRUZ CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CRUZ CONSTRUCTION in 227 SAPPHIRE DR., NEW BRAUNFELS, TX 78130 (NAICS 238160). OSHA activity number 345295224.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRUZ CONSTRUCTION
- Site address
- 227 SAPPHIRE DR.
- City
- NEW BRAUNFELS
- State
- TX
- ZIP
- 78130
- Mailing
- 3630 W. MARTIN, SAN ANTONIO, TX 78207
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Aug 12, 2021
- Penalty
- Initial $1,755 · Current $1,755
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: On or about May 6, 2021, and at times prior thereto, employees were working in a construction area without the use of hardhats where overhead hazards exist, exposing employees to struck by hazards.
Recent events (1)
- — Z (S) $1755
1926.452 J02
- Issued
- Aug 12, 2021
- Penalty
- Initial $2,341 · Current $2,341
General-duty citation text
29 CFR 1926.452(j)(2):Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. On or about May 6, 2021, employees were working from a Louisville pump jack that was not properly anchored at heights above 10 feet, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $2341
1926.501 B13
- Issued
- Aug 12, 2021
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. On or about May 6, 2021, and at times prior thereto, employees were installing exterior siding on residential townhomes at heights above 6 feet without the use of fall protection, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $1865
1926.1053 B01
- Issued
- Aug 12, 2021
- Penalty
- Initial $1,268 · Current $1,268
General-duty citation text
29 CFR 1926.1053(b)(1):Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. On or about May 6, 2021, and at times prior thereto, employees were accessing the roof of residential town-homes by means of a ladder that did not extend at least 3 feet above the upper landing surface, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $1268
1926.1053 B04
- Issued
- Aug 12, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4):Ladders were used for purposes other than the purposes for which they were designed. On or about May 6, 2021, and at times prior thereto, employees were improperly utilizing a portable free-standing ladder to install exterior siding at elevated heights of a residential town-home under construction, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $0
More inspections at Cruz Construction
View Cruz Construction's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345295224.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.