Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TEC in 11207 W LOOP 1604 N (MISSION PARK CHAPEL-NEW CONSTRUCTION), HELOTES, TX 78023 (NAICS 238140). OSHA activity number 345295547.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TEC — free Get an email when a new federal OSHA severe-injury report for TEC is published. One employer, no account, unsubscribe in one click.
Establishment
TEC
Site address
11207 W LOOP 1604 N (MISSION PARK CHAPEL-NEW CONSTRUCTION)
City
HELOTES
State
TX
ZIP
78023
Mailing
8102 GLEN LARK, SAN ANTONIO, TX 78239
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 10, 2021
Penalty
Initial $3,511 · Current $1,500 Reduced
29 CFR  1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary:  On or about May 6, 2021, and times prior thereto, employees were exposed to fall hazard while working on scaffolds that did not have planks installed covering the width of scaffold.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3511

1926.451 B07

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 10, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.451(b)(7):On scaffolds where platforms are overlapped to create a long platform, the overlap was not at least 12 inches (30 cm) and the platforms were not nailed together or otherwise restrained to prevent movement:  On or about May 6, 2021, and times prior thereto, employees were exposed to a fall hazard while working on scaffolds that did not have adequate overlapping planks at joining sections.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 10, 2021
Penalty
Initial $3,511 · Current $1,500 Reduced
29 CFR  1926.451(c)(2)(i): Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:  On or about May 6, 2021 and times prior thereto, employees were exposed to fall hazard while working on scaffolds that did not have footings  that were secured or had mud sills.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3511

1926.451 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 10, 2021
Penalty
Initial $3,511 · Current $1,500 Reduced
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not use:  On or about May 6, 2021, and times prior thereto, employees were exposed to a fall hazard while using scaffold planks as a ramp and supported on the top of cross braces for access and egress.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3511

1926.452 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 10, 2021
Penalty
Initial $3,511 · Current $0 Reduced
29 CFR  1926.452(c)(2): All cross braces were not of such length so as to automatically square and align vertical members such that the erected scaffold was always plumb, level, and square:  On or about May 6, 2021 and times prior thereto, employees were exposed to fall hazard while working on scaffold that did not have cross bracing installed securely on all sections in accordance with manufacturer's instructions and scaffold type.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3511

1926.451 F07

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 10, 2021
Abate by
Oct 28, 2021
Penalty
Initial $4,096 · Current $1,500 Reduced
29 CFR  1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:  On or about May 6, 2021, and times prior thereto, employees were exposed to a fall hazard while working on a scaffold that was not erected under the supervision of a competent person.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4096

1926.454 A

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 10, 2021
Abate by
Oct 28, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  On or about May 6, 2021, and times prior thereto, employees were exposed to a fall hazard while working on a scaffold without hazard recognition training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View TEC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345295547.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.