Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.C.E. HEAT EXCHANGERS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of R.C.E. HEAT EXCHANGERS, LLC in 602 THOMAS ROAD, MONROEVILLE, PA 15146 (NAICS 332410). OSHA activity number 345298061.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.C.E. Heat Exchangers, LLC — free Get an email when a new federal OSHA severe-injury report for R.C.E. Heat Exchangers, LLC is published. One employer, no account, unsubscribe in one click.
Site address
602 THOMAS ROAD
City
MONROEVILLE
State
PA
ZIP
15146
Mailing
3165 FOLSAM ROAD NW, CARROLLTON, OH 44615
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
13
Ownership type
A

2 citations on file for this inspection.

1910.147 D03

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Oct 21, 2021
Penalty
Initial $5,461 · Current $0 Reduced
29 CFR  1910.147(d)(3):  All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):     (a) Jobsite, 602 Thomas Road, Monroeville, PA 15146:  On or about May 10, 2021 employees did not ensure that devices needed to control the energy to a Smithco brand air cooled ammonia condenser were physically located and operated in a manner as to isolate the equipment from the energy sources.   An employee received serious injuries from exposure to ammonia that was released after a plug was removed from a Smithco brand air cooled ammonia condenser located outside the building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5461

1910.147 F02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 21, 2021
Penalty
Initial $0 · Current $4,000
29 CFR  1910.147(f)(2)(i):  When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures:  (a) Jobsite, 602 Thomas Road, Monroeville, PA 15146:  On or about May 10, 2021, when outside servicing personnel (employees of R.C.E. Heat Exchangers, LLC) were engaged in maintenance activities on a Smithco brand air cooled ammonia condenser at this facility, the onsite employer (Montauk Energy Holdings, LLC) and the outside employer did not inform each other of their respective lockout or tagout procedures.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345298061.