Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROSERV OPERATIONS, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PROSERV OPERATIONS, LLC in 15151 SOMMERMEYER ST., HOUSTON, TX 77041 (NAICS 332912). OSHA activity number 345305353.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Proserv Operations, LLC — free Get an email when a new federal OSHA severe-injury report for Proserv Operations, LLC is published. One employer, no account, unsubscribe in one click.
Site address
15151 SOMMERMEYER ST.
City
HOUSTON
State
TX
ZIP
77041
Mailing
15151 SOMMERMEYER ST., HOUSTON, TX 77041
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332912
Employees
64
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 26, 2021
Abate by
Aug 12, 2021
Penalty
Initial $7,022 · Current $4,213 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about May 13, 2021, in Bay #1, employees were working with a combination belt and disc sander without a guard to cover unused portion of the sander or the nip point between the belt sander and rotating pulley exposing employees to caught-by hazards.
Recent events (2)
  • — I (S) $4213.2
  • — Z (S) $7022

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Jul 26, 2021
Abate by
Aug 12, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about May 13, 2021, in Bay #1, electrical equipment was powered by power strips daisy chained with extension cords which is not in accordance with listing and labeling instructions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Jul 26, 2021
Abate by
Aug 12, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about May 13, 2021, in Bay #1, several flexible cords that were used to provided power to multiple permanently fixed machines without permanent hard wired fixtures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345305353.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.