Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLAMBEAU, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FLAMBEAU, INC. in 1468 WOLF CREEK TRAIL, SHARON CENTER, OH 44274 (NAICS 326199). OSHA activity number 345310312.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flambeau, INC. — free Get an email when a new federal OSHA severe-injury report for Flambeau, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FLAMBEAU, INC.
Site address
1468 WOLF CREEK TRAIL
City
SHARON CENTER
State
OH
ZIP
44274
Mailing
1468 WOLF CREEK TRAIL, SHARON CENTER, OH 44274
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
500
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Repeat Gravity 10 1 instance 40 exposed
Issued
Sep 30, 2021
Abate by
Oct 20, 2021
Penalty
Initial $30,037 · Current $19,524 Reduced
29 CFR  1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   On or about May 12, 2021, the employer failed to develop and implement a full site specific written program for the control of hazardous energy for equipment and machinery to include but not limited to  the Sterling blow mold presses (14 total) that have energy sources to include but are not limited to mechanical, electrical, hydraulic and pneumatic.  NOTE:  The employer was previously cited for a violation of this occupational safety and health standard or it's equivalent standard which was contained in OSHA Inspection #1408053, citation 2, item 1, which was affirmed as final order on May 7, 2020, with respect to the same workplace location as detailed in this inspection.
Recent events (2)
  • — I (R) $19524
  • — Z (R) $30037

1910.147 D

Repeat Gravity 10 1 instance 1 exposed
Issued
Sep 30, 2021
Abate by
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d):The application of energy control (lockout or tagout) actions were not done in the following sequence:   (1) prepare for shutdown, (2) shut down machine or equipment, (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device by authorized employee, (5) relieve, disconnect, restrain or otherwise render safe all stored or residual energy, (6) verify that isolation and deenergization of the machine or equipment have been accomplished:  On or about May 12, 2021, the employer failed to ensure that all of the energy sources to Press #3 was locked and tagged out prior to an employee entering through the gated double door in order to access the inside of the mold to retrieve a part that was stuck.  The sequential order of the steps was not followed prior to the employee performing this task.  The press was not locked and tagged out.   NOTE:  The employer was previously cited for a violation of this occupational safety and health standard or it's equivalent standard which was contained in OSHA Inspection #1408053, citation 1, item 3, which was affirmed as final order on May 7, 2020, with respect to the same workplace location as detailed in this inspection.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.147 C06 I

Repeat Gravity 10 1 instance 40 exposed
Issued
Sep 30, 2021
Abate by
Nov 4, 2021
Penalty
Initial $30,037 · Current $19,524 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   On or about May 12, 2021, the employer failed to ensure that a periodic inspection of their written lock out tag out control of hazardous energy procedures was conducted to ensure that is was up to date and effective.  The employer had an outdated and non site specific partially written program in place that had not been updated or reviewed since 2018.  NOTE:  The employer was previously cited for a violation of this occupational safety and health standard or it's equivalent standard which was contained in OSHA Inspection #1408053, citation 2, item 2, which was affirmed as final order on May 7, 2020, with respect to the same workplace location as detailed in this inspection.
Recent events (2)
  • — I (R) $19524
  • — Z (R) $30037

1910.147 C06 I B

Repeat Gravity 5 1 instance 40 exposed
Issued
Sep 30, 2021
Abate by
Nov 4, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i)(B): The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified:  On or about May 12, 2021, the employer failed to ensure that a periodic inspection of their written lock out tag out control of hazardous energy procedures was conducted to ensure that any deviations or inadequacies were identified and corrected.  The employer had an outdated written program which was not site specific and all inclusive  which was dated 2018 and had not been reviewed or updated since.  NOTE:  The employer was previously cited for a violation of this occupational safety and health standard or it's equivalent standard which was contained in OSHA Inspection #1408053, citation 2, item 2, which was affirmed as final order on May 7, 2020, with respect to the same workplace location as detailed in this inspection.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.147 C07 III B

Repeat Gravity 5 1 instance 40 exposed
Issued
Sep 30, 2021
Abate by
Nov 4, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures:   On or about May 12, 2021, the employer failed to ensure that a periodic inspection of their written lock out tag out control of hazardous energy procedures was conducted to ensure that is was up to date and effective.  The employer had an outdated and not site specific partial written program in place that had not been updated or reviewed since 2018.  NOTE:  The employer was previously cited for a violation of this occupational safety and health standard or it's equivalent standard which was contained in OSHA Inspection #1408053, citation 2, item 2, which was affirmed as final order on May 7, 2020, with respect to the same workplace location as detailed in this inspection.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.212 A01

Repeat Gravity 10 12 instances 40 exposed
Issued
Sep 30, 2021
Abate by
Jun 30, 2022
Penalty
Initial $30,037 · Current $19,524 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On or about May 12, 2021, the employer failed to ensure that effective guarding was in place on the Blow Mold Press Machines, including the Sterling Press Molds #1, 2, 4, 5, 6, 7,  9, 10 11, 12, 13 and 17.  Each press has varying degrees of lack of effective guarding, such as but not limited to,  short light curtains, no light curtain, no bump door strip for the main front mechanical gate doors and double redundancy measures.  Since the initial inspection in 2019 (inspection #1408053), the employer has only fully modified press #3, while the rest, except for press #8 and 10 which have had the safety mats removed and short light curtains installed just inside the mechanical gate doors of the presses.  These measures do not prevent the employees from being able to reach or step over the light curtain field in order to access the press and dies inside.  Employees are exposed to possible struck-by and/or caught in between hazards  due to this.  NOTE:  The employer was previously cited for a violation of this occupational safety and health standard or it's equivalent standard which was contained in OSHA Inspection #1408053, citation 1, item 5, which was affirmed as final order on May 7, 2020, with respect to the same workplace location as detailed in this inspection.
Recent events (3)
  • — P (R) $19524
  • — I (R) $19524
  • — Z (R) $30037

View Flambeau, INC.'s full OSHA safety record →