SPRINGFIELD, MO —
OSHA Inspection: JENFAB CLEANING SOLUTIONS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JENFAB CLEANING SOLUTIONS in 1435 N. ALLIANCE, SPRINGFIELD, MO 65802 (NAICS 333318). OSHA activity number 345320048.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JENFAB CLEANING SOLUTIONS
- Site address
- 1435 N. ALLIANCE
- City
- SPRINGFIELD
- State
- MO
- ZIP
- 65802
- Mailing
- 1435 N. ALLIANCE, SPRINGFIELD, MO 65802
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333318
- Employees
- 78
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C05 II D
- Issued
- Sep 23, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $5,461 · Current $2,731 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D):Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): At a worksite located at 1435 N. Alliance, Springfield, MO: Employees were exposed to electrical hazards. a: Two lockout tagout devices did not identify the employee applying the lockout tagout device when locking out the 460 Volt Main electrical panel along the South Wall in Final Assembly. b: One lockout tagout device did not identify the employee applying the lockout tagout device to the 230 Volt Three phase electrical panel mounted to blue sheet metal in Final Assembly. c: One lockout tagout device did not identify the employee applying the lockout tagout device to the 208 volt three phase electrical panel mounted to blue sheet metal in Final Assembly.
Recent events (2)
- — I (S) $2730.5
- — Z (S) $5461
1910.147 C07 I A
- Issued
- Sep 23, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $9,557 · Current $4,779 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: At a worksite located at 1435 N. Alliance, Springfield, MO: An employee was exposed to electrical hazards. An employee was required to test industrial washers which were connected 460 volts of electricity and did not receive authorized employee training on Lockout tagout training including training on when lockout tagout training was required, recognition of the hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.
Recent events (2)
- — I (S) $4778.5
- — Z (S) $9557
1910.303 B02
- Issued
- Sep 23, 2021
- Penalty
- Initial $9,557 · Current $4,779 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: At a worksite located at 1435 N. Alliance, Springfield, MO: Employees were exposed to electrical hazards. Employees in the Final Assembly Area, were using the 460 volt electrical box attached to blue sheet metal to test parts washing machines. The Orange Frontal Rotary Handle Disconnect Switch for the 460 volt electrical box was not connected to the interior T handle and would not disconnect the power. On or about May 12, 2021, an employee was injured by electrical shock when the electrical wiring cable he was going to use to test an industrial washing machine was live.
Recent events (2)
- — I (S) $4778.5
- — Z (S) $9557
1910.304 G05
- Issued
- Sep 23, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $5,461 · Current $2,731 Reduced
General-duty citation text
29 CFR 1910.304(g)(5):The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: At a worksite located at 1435 N. Alliance, Springfield, MO: Employees were exposed to electrical hazards. The TPI Industrial Pedestal fan was not ground as the ground pin was absent.
Recent events (2)
- — I (S) $2730.5
- — Z (S) $5461
1910.305 B01 II
- Issued
- Sep 23, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $5,461 · Current $2,731 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: At a worksite located at 1435 N. Alliance, Springfield, MO: Employees were exposed to electrical hazards. a: There was an open knockout on the top of the 230 Volt three phase electrical breaker box attached to the blue sheet metal in Final Assembly/Testing. b: There was an open knockout on the left side facing the 460 volt main panel box against the South Wall of Final Assembly/Testing.
Recent events (2)
- — I (S) $2730.5
- — Z (S) $5461
More inspections in this industry (NAICS 333318)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345320048.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.