Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CF&I STEEL, L.P.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CF&I STEEL, L.P. in 2100 SOUTH FREEWAY, PUEBLO, CO 81004 (NAICS 332312). OSHA activity number 345336200.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CF&I Steel, L.P. — free Get an email when a new federal OSHA severe-injury report for CF&I Steel, L.P. is published. One employer, no account, unsubscribe in one click.
Establishment
CF&I STEEL, L.P.
Site address
2100 SOUTH FREEWAY
City
PUEBLO
State
CO
ZIP
81004
Mailing
1612 E. ABRIENDO, PUEBLO, CO 81004
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
1005
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 19, 2021
Abate by
Jan 10, 2022
Penalty
Initial $13,653 · Current $13,653
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion hazards:  (a) On or about  May 29, 2021, and at times prior, employees were exposed to explosion hazards in that the employer failed to develop and implement effective controls to prevent the introduction of water into molten metal within the #5 Electric Arc Furnace (EAF).  At least three workers suffered serious burns when a balcony cooling panel on the #5 EAF leaked a large quantity of water into molten steel and caused an explosion.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $13653
  • — Z (S) $13653

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 19, 2021
Abate by
Jan 10, 2022
Penalty
Initial $13,653 · Current $13,653
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to thermal and struck-by hazards:  (a) On or about  May 29, 2021, and at times prior, employees were exposed to thermal and struck-by hazards in that the employer failed to identify and guard the hazard zone around the #5 Electric Arc Furnace allowing workers to enter hazardous areas, including but not limited to the area in front of the slag door of the furnace.  The hazard zone on and around the furnace was not clearly marked and there were no physical guards to prevent workers from entering the furnace area during operations.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $13653
  • — Z (S) $13653

1910.120 Q01

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 19, 2021
Abate by
Jan 10, 2022
Penalty
Initial $13,653 · Current $13,653
29 CFR  1910.120(q)(1): The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations:    (a) On or about  May 29, 2021, and at times prior, employees were exposed to explosion, thermal and struck-by hazards in that the employer failed to develop and implement an effective emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations during a series of explosions caused by the presence of water introduction into molten metal that occurred in the #5 Electric Arc Furnace.  Personnel were directed to perform response activities related to the explosions.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $13653
  • — Z (S) $13653

1910.120 Q02 IX

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 19, 2021
Abate by
Feb 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.120(q)(2)(ix): The emergency response plan did not address, to the extent not addressed elsewhere, emergency alerting and response procedures:   (a) On or about  May 29, 2021, and at times prior, employees were exposed to explosion, thermal and struck-by hazards in that the employer failed to  provide an effective emergency alerting and response process, such as but not limited to, an audible and visual signal system for warning workers of danger, during a series of explosions caused by water introduction into molten metal that occurred in the #5 Electric Arc Furnace. At least three workers suffered serious injuries during the explosion where workers were not effectively warned to evacuate the furnace floor.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.120 Q02 XI

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 19, 2021
Abate by
Jan 10, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.120(q)(2)(xi): The emergency response plan did not address, to the extent not addressed elsewhere,  personal protective equipment and emergency equipment:     (a) On or about  May 29, 2021, and at times prior, employees were exposed to explosion, thermal and struck-by hazards in that the employer failed to develop and implement an effective emergency response plan that addressed personal protective equipment (PPE) that would be necessary for employees to use during response activities.   The employer did not ensure that proper PPE was used by workers entering  hazardous areas, including but not limited to the area in front of the slag door, on the #5 Electric Arc Furnace during emergency response activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View CF&I Steel, L.P.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345336200.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.