PONTIAC, IL —
OSHA Inspection: B & K TECHNOLOGY SOLUTIONS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of B & K TECHNOLOGY SOLUTIONS INC. in 902 N HAZEL STREET, PONTIAC, IL 61764 (NAICS 541512). OSHA activity number 345338214.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B & K TECHNOLOGY SOLUTIONS INC.
- Site address
- 902 N HAZEL STREET
- City
- PONTIAC
- State
- IL
- ZIP
- 61764
- Mailing
- 902 N HAZEL STREET, PONTIAC, IL 61764
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541512
- Employees
- 81
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L01 I
- Issued
- Oct 28, 2021
- Abate by
- Nov 22, 2021
- Penalty
- Initial $7,022 · Current $3,511 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about June 1, 2021, prior to allowing an employee to use the power stocker powered industrial truck, the employer did not ensure that each operator had completed formal instruction training, practical training, and an evaluation.
Recent events (2)
- — I (S) $3511
- — Z (S) $7022
1910.178 L06
- Issued
- Oct 28, 2021
- Abate by
- Nov 22, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: On or about June 1, 2021, the employer did not certify that each operator of the powered industrial trucks had been trained and evaluated in the safe operation of the powered industrial trucks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Oct 28, 2021
- Penalty
- Initial $8,778 · Current $4,389 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) with defect(s) or in way unsafe had not been withdrawn from service until restored to safe operating condition(s): On or about June 1, 2021, an employee was exposed to injury because the shield around the mast was missing on the Ballymore Powered Industrial Truck, Model PS-10, Serial Number 286, and the powered industrial truck was not taken out of service until it had been restored to safe operating condition.
Recent events (2)
- — I (S) $4389
- — Z (S) $8778
1910.303 B02
- Issued
- Oct 28, 2021
- Abate by
- Nov 8, 2021
- Penalty
- Initial $7,022 · Current $3,511 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling: a. On or about June 1, 2021, employees working near the cardboard baler were exposed to electrical hazards because a Tripp-Lite 6 outlet relocatable power tap relocatable was series connected to an extension cord. b. On or about June 1, 2021, employees working near the cardboard baler were exposed to electrical hazards because a 6 outlet relocatable power tap relocatable was series connected to an extension cord.
Recent events (2)
- — I (O) $3511
- — Z (S) $7022
1910.305 C04
- Issued
- Oct 28, 2021
- Abate by
- Nov 8, 2021
- Penalty
- Initial $7,022 · Current $3,511 Reduced
General-duty citation text
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: On or about June 1, 2021, employees working near the cardboard baler were exposed to electrical hazards while using the switch because there was no faceplate.
Recent events (2)
- — I (O) $3511
- — Z (S) $7022
More inspections at B & K Technology Solutions INC.
View B & K Technology Solutions INC.'s full OSHA safety record →
More inspections in this industry (NAICS 541512)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345338214.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.