OSHA Inspection: CG ROOFING GROUP, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of CG ROOFING GROUP, LLC in 830 OAK STREET, JACKSONVILLE, FL 32204 (NAICS 238160). OSHA activity number 345364210.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CG Roofing Group, LLC — free Get an email when a new federal OSHA severe-injury report for CG Roofing Group, LLC is published. One employer, no account, unsubscribe in one click.
Site address
830 OAK STREET
City
JACKSONVILLE
State
FL
ZIP
32204
Mailing
4320 DEERWOOD LAKE PKWY STE 101-133, JACKSONVILLE, FL 32216
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 2 instances 3 exposed
Issued
Aug 13, 2021
Abate by
Sep 9, 2021
Penalty
Initial $5,461 · Current $3,277 Reduced
29 CFR  1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a. On or about June 12, 2021, and at times prior, at the west side of the building, the employer exposed subcontracted employees of Inversiones R.A.L. 23 LLC to a 32 feet fall hazard, in that an employee performing roofing work on a 9:12 pitch roof was not wearing a personal fall arrest system.  b. On or about June 12, 2021, and at times prior, at the west side of the building, the employer exposed subcontracted employees of Inversiones R.A.L. 23 LLC to a 32 feet fall hazard, in that two employees performing roofing work on a 9:12 pitch roof were not wearing their personal fall arrest systems as intended and according to manufacturer's instructions.  The employees were not connected to the D-ring at the back, but on components of their body harness.
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

1926.503 A02 II

Other-than-serious 1 instance 3 exposed
Issued
Aug 13, 2021
Abate by
Sep 9, 2021
Penalty
Initial $438 · Current $263 Reduced
29 CFR  1926.503(a)(2)(ii):The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:  a. On or about June 12, 2021, at the west side of the building, the employer exposed sub-contracted employees to a fall hazard of 32 feet in that employees were not trained by a competent person in the correct procedures for erecting, maintaining and inspecting the fall protection system on the 9:12 pitch roofing job at the site.
Recent events (2)
  • — I (O) $262.8
  • — Z (O) $438

View CG Roofing Group, LLC's full OSHA safety record →