Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PAESE CONSTRUCTION LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PAESE CONSTRUCTION LLC in 48 HIGHLAND AVE, DEMAREST, NJ 07627 (NAICS 236115). OSHA activity number 345375323.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paese Construction LLC — free Get an email when a new federal OSHA severe-injury report for Paese Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
48 HIGHLAND AVE
City
DEMAREST
State
NJ
ZIP
07627
Mailing
266 LAUREL AVE, KEARNY, NJ 07032
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.451 C02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 6, 2021
Penalty
Initial $4,096 · Current $2,250 Reduced
29 CFR  1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.   a- Building Exterior(East Side): An employee engaged in siding activities installing Azek board was exposed to fall hazards of approximately 23 ft as the pump jack scaffold support legs were not provided base plates exposing the employee to scaffold displacement.  Condition noted on or about 06/17/2021
Recent events (3)
  • — J (S) $2250
  • — C (S) $4096
  • — Z (S) $4096

1926.452 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 6, 2021
Penalty
Initial $4,096 · Current $2,250 Reduced
29 CFR  1926.452(j)(2): Poles of pump jack scaffold(s) were not secured to the structure by rigid triangular bracing, or equivalent, at the bottom, top and other points as necessary:  a- Building Exterior(East Side): An employee engaged in siding activities installing Azek board was exposed to fall hazards of approximately 23 ft as the pump jack scaffold supports were not plumb and square as triangular bracing had not been installed at the scaffold base.  Condition noted on or about 06/17/2021
Recent events (3)
  • — J (S) $2250
  • — C (S) $4096
  • — Z (S) $4096

1926.451 G01

Willful Gravity 10 1 instance 1 exposed
Issued
Aug 6, 2021
Penalty
Initial $27,306 · Current $15,000 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection.  a- Building Exterior(East Side): An employee engaged in siding work during the installation of Azek board fell approximately 23ft down a a cement shaft as a means of fall protection was not utilized. Condition noted on or about 06/17/2021
Recent events (3)
  • — J (W) $15000
  • — C (W) $27306
  • — Z (W) $27306

View Paese Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345375323.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.