On , OSHA opened a planned safety inspection of MATT MERTZ PLUMBING INC. in 5839 PIERCE STREET, PITTSBURGH, PA 15232 (NAICS 237110). OSHA activity number 345393847.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MATT MERTZ PLUMBING INC.
- Site address
- 5839 PIERCE STREET
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15232
- Mailing
- 4693 PEOPLES ROAD, PITTSBURGH, PA 15237
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.652 D02
- Issued
- Aug 20, 2021
- Penalty
- Initial $4,096 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.652(d)(2): Manufactured materials and equipment used for protective systems were not used and maintained in a manner that was consistent with the recommendations of the manufacturer: (a) Job site, 5839 Pierce Street, Pittsburgh, PA: On or about June 30th 2021 employees were not protected from cave in hazards while using an Ultra Shore S Series trench box. The box was being used in an excavation that was approximately 16 feet in depth, while the tabulated data for this particular box states : In no case can the "S" series shield be used in excavations exceeding 12 feet in depth without conducting the proper earth pressure calculations.
Recent events (3)
- — F (O) $2100
- — C (S) $4096
- — Z (S) $4096
1926.652 G01 II
- Issued
- Aug 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(g)(1)(ii):Shields were not installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads: (a) Job site, 5839 Pierce Street, Pittsburgh, PA: On or about June 30th 2021 employees were not protected from cave in hazards while using an Ultra Shore S Series trench box. The box was being used in an excavation that was approximately 16 feet in depth, the box was not supported in order to prevent any inadvertent lateral movement of the trench box.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Matt Mertz Plumbing INC.
View Matt Mertz Plumbing INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345393847.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.