Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRINTPACK, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRINTPACK, INC. in 1400 ABBOTT DRIVE, ELGIN, IL 60123 (NAICS 323111). OSHA activity number 345408835.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Printpack, INC. — free Get an email when a new federal OSHA severe-injury report for Printpack, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRINTPACK, INC.
Site address
1400 ABBOTT DRIVE
City
ELGIN
State
IL
ZIP
60123
Mailing
1400 ABBOTT DRIVE, ELGIN, IL 60123
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
140
Ownership type
A

1 citation on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 7 exposed
Issued
Oct 28, 2021
Abate by
May 2, 2022
Penalty
Initial $13,653 · Current $13,653
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   (1) prepare for shut down by recognizing energy hazards and its controls,  (2) turn off and shut down the machines,  (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source,  (4) affix lockout or tagout devices to each energy isolating device,  (5) render safe all potentially hazardous stored or residual energy,  (6) verify that isolation and de-energization of the machine or equipment have been accomplished.   (a) Press department, Shiavi press No. 6  - on or about June 21, 2021, the employer did not ensure that press operators had isolated the hazardous energy prior to using a hand tool to remove debris in the danger zone from the rotating sleeve roller. Because the equipment was not locked out, employees had their hands exposed to an unguarded in-going nip point.   (b) Press department, press No. 2 - on or about July 9, 2021, the employer did not ensure that press operators had isolated the hazardous energy prior to sticking doctor blade for ink buildup removal in the danger zone. Because the equipment was not locked out, employees had their hands exposed to an unguarded in-going nip point.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • — P (S) $13653
  • — I (S) $13653
  • — Z (S) $13653

View Printpack, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345408835.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.