Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JORGE MORENO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JORGE MORENO in 200 COLE ST. BLDG.: 8, PRINCETON, TX 75407 (NAICS 238140). OSHA activity number 345417885.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jorge Moreno — free Get an email when a new federal OSHA severe-injury report for Jorge Moreno is published. One employer, no account, unsubscribe in one click.
Establishment
JORGE MORENO
Site address
200 COLE ST. BLDG.: 8
City
PRINCETON
State
TX
ZIP
75407
Mailing
2342 LARRY DR., DALLAS, TX 75228
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 2 instances 1 exposed
Issued
Aug 23, 2021
Abate by
Sep 17, 2021
Penalty
Initial $4,505 · Current $4,505
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary:  (a) On or about July 14, 2021, an employee working on the second tier of self-supported tubular welded end frame scaffolding was not protected from a fall hazard of approximately fourteen (14) feet in that the scaffolding was not fully planked.  (b) On or about July 14, 2021, an employee working on the second tier at a corner of self-supported tubular welded end frame scaffolding was not protected from a fall hazard of approximately fourteen (14) feet in that the scaffolding was not fully planked.
Recent events (1)
  • — Z (S) $4505

1926.451 B03

Serious Gravity 10 2 instances 1 exposed
Issued
Aug 23, 2021
Abate by
Sep 17, 2021
Penalty
Initial $4,505 · Current $4,505
29 CFR 1926.451(b)(3):The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: Note:  See exceptions in paragraphs (b)(3)(i) and (ii) of this section.  (a) On or about July 14, 2021, an employee working on the second tier of self-supported tubular welded end frame scaffolding was not protected from a fall hazard of approximately fourteen (14) feet in that the scaffolding was approximately 20 inches from the face of the work and no fall protection was provided.  (b) On or about July 14, 2021, an employee working on the second tier of self-supported tubular welded end frame scaffolding at the corner was not protected from a fall hazard of approximately fourteen (14) feet in that the scaffolding was approximately 20 inches from the face of the work and no fall protection was provided.
Recent events (1)
  • — Z (S) $4505

1926.451 E01

Repeat Gravity 10 1 instance 1 exposed
Issued
Aug 23, 2021
Abate by
Sep 17, 2021
Penalty
Initial $9,011 · Current $9,011
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access:  (a) On or about July 14, 2021, at least one employee was accessing self-supported welded tubular end frame scaffolding by using the end frames and cross braces exposing him to a fall hazard of up to approximately fourteen (14) feet to the ground below.  JORGE MORENO WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD (1926.451(e)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1262565, CITATION NUMBER 01, ITEM NUMBER 002, AND WAS AFFIRMED AS A FINAL ORDER ON 01/09/2018, WITH RESPECT TO A WORKPLACE LOCATED AT 4005 GASTON AVE, DALLAS, TX 75246.
Recent events (1)
  • — Z (R) $9011

View Jorge Moreno's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345417885.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.