OSHA Inspection: ROOFED RIGHT AMERICA LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROOFED RIGHT AMERICA LLC in 536 MAIN ST., ALLENTON, WI 53002 (NAICS 238160). OSHA activity number 345436794.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roofed Right America LLC — free Get an email when a new federal OSHA severe-injury report for Roofed Right America LLC is published. One employer, no account, unsubscribe in one click.
Site address
536 MAIN ST.
City
ALLENTON
State
WI
ZIP
53002
Mailing
429 W BODEN STREET, MILWAUKEE, WI 53207
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
25
Ownership type
A

2 citations on file for this inspection.

1926.502 D06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $3,901 · Current $2,731 Reduced
29 CFR  1926.502(d)(6)(i): A snap hook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snap hook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snap hook such that unintentional disengagement could occur by the connected object being able to depress the snap hook keeper and release itself.   (a) On or about July 23, 2021, at the construction site located at 536 Main St, Allenton WI, employees were exposed to a fall hazard of approximately 21 8/10 feet and had the snap hook connected directly to webbing of the vertical life line.
Recent events (2)
  • — I (S) $2730.7
  • — Z (S) $3901

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:   (a) On or about July 23, 2021, at the construction site located at 536 Main St, Allenton WI, an employee was tied off with a harness and vertical lifeline and fell through the roof opening where they were replacing roof sections. The employee fell 21 8/10 feet and hit the ground. The employee free fell more than 6 vertical feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Roofed Right America LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345436794.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.