PHILADELPHIA, PA —
OSHA Inspection: MAYFIELD SITE CONTRACTORS, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of MAYFIELD SITE CONTRACTORS, INC. in 700 RAMONA AVE, PHILADELPHIA, PA 19120 (NAICS 238910). OSHA activity number 345444087.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAYFIELD SITE CONTRACTORS, INC.
- Site address
- 700 RAMONA AVE
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19120
- Mailing
- 596 SWEDELAND ROAD, KING OF PRUSSIA, PA 19406
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 100
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.21 B02
- Issued
- Jan 25, 2022
- Abate by
- Feb 11, 2022
- Penalty
- Initial $10,151 · Current $10,151
General-duty citation text
29 CFR 1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury. a) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 27, 2021, the employer did not instruct the employees in the recognition and avoidance of collapse hazard. Employees were exposed to a collapse hazard while leveling loose stone adjacent to an unprotected wall.
Recent events (3)
- — R (S) $10151
- — C (S) $10151
- — Z (S) $10151
1926.651 K02
- Issued
- Jan 25, 2022
- Abate by
- Jan 31, 2022
- Penalty
- Initial $10,151 · Current $10,151
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible collapse, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. a) Jobsite: 700 Ramona Ave, Philadelphia, PA - At various times in July 2021, the competent person was aware of conditions, such as but not limited to excavation collapses, that could affect the stability of the approximately 20 foot shear excavated wall and did not take precautions or removed the employees constructing the retaining wall from exposure to collapse hazards.
Recent events (3)
- — R (S) $10151
- — C (S) $10151
- — Z (S) $10151
1926.652 C
- Issued
- Jan 25, 2022
- Abate by
- Jan 31, 2022
- Penalty
- Initial $10,151 · Current $10,151
General-duty citation text
29 CFR 1926.652(c): Designs of support systems, shield systems, and other protective systems shall be selected and constructed by the employer or his designee and shall be in accordance with the requirements of paragraph (c)(1); or, in the alternative, paragraph (c)(2); or, in the alternative, paragraph (c)(3); or, in the alternative, paragraph (c)(4). a) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 26, 2021 the employer's protective system was not drawn or selected from the manufacturer's or other tabulated data, or approved by a registered professional engineer to determine if the selection and design of the protective system was appropriate to the excavation work, thereby exposing employees to collapse hazards.
Recent events (3)
- — R (S) $10151
- — C (S) $10151
- — Z (S) $10151
1926.652 A01
- Issued
- Jan 25, 2022
- Abate by
- Jan 31, 2022
- Penalty
- Initial $145,027 · Current $145,027
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from collapses by an adequate protective system designed in accordance with 1926 Subpart P. a) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 26, 2021 the employer did not ensure employees working in front of an approximately 20 foot tall shear excavated wall were protected from collapses by the use of an adequate protective system. The employer allowed the use of 8' x 14' tall steel plate against the excavated wall, which was inadequate for protection against collapses during retaining wall construction activities, exposing employees to collapse hazards. b) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 27, 2021 the employer did not ensure employees working in front of an approximately 20 foot tall shear excavated wall were protected from collapses with the use of a protective system. An employee was working within 3 feet of the unprotected wall as it collapsed, thus killing the employee.
Recent events (3)
- — R (S) $145027
- — C (W) $145027
- — Z (W) $145027
More inspections at Mayfield Site Contractors, INC.
View Mayfield Site Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345444087.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.