Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAYFIELD SITE CONTRACTORS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of MAYFIELD SITE CONTRACTORS, INC. in 700 RAMONA AVE, PHILADELPHIA, PA 19120 (NAICS 238910). OSHA activity number 345444087.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mayfield Site Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Mayfield Site Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
700 RAMONA AVE
City
PHILADELPHIA
State
PA
ZIP
19120
Mailing
596 SWEDELAND ROAD, KING OF PRUSSIA, PA 19406
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
238910
Employees
100
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 25, 2022
Abate by
Feb 11, 2022
Penalty
Initial $10,151 · Current $10,151
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury.  a) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 27, 2021, the employer did not instruct the employees in the recognition and avoidance of collapse hazard.  Employees were exposed to a collapse hazard while leveling loose stone adjacent to an unprotected wall.
Recent events (3)
  • — R (S) $10151
  • — C (S) $10151
  • — Z (S) $10151

1926.651 K02

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 25, 2022
Abate by
Jan 31, 2022
Penalty
Initial $10,151 · Current $10,151
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible collapse, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety.  a) Jobsite: 700 Ramona Ave, Philadelphia, PA -  At various times in July 2021, the competent person was aware of conditions, such as but not limited to excavation collapses, that could affect the stability of the approximately 20 foot shear excavated wall and did not take precautions or removed the employees constructing the retaining wall from exposure to collapse hazards.
Recent events (3)
  • — R (S) $10151
  • — C (S) $10151
  • — Z (S) $10151

1926.652 C

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 25, 2022
Abate by
Jan 31, 2022
Penalty
Initial $10,151 · Current $10,151
29 CFR  1926.652(c): Designs of support systems, shield systems, and other protective systems shall be selected and constructed by the employer or his designee and shall be in accordance with the requirements of paragraph (c)(1); or, in the alternative, paragraph (c)(2); or, in the alternative, paragraph (c)(3); or, in the alternative, paragraph (c)(4).  a) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 26, 2021 the employer's protective system was not drawn or selected from the manufacturer's or other tabulated data, or approved by a registered professional engineer to determine if the selection and design of the protective system was appropriate to the excavation work, thereby exposing employees to collapse hazards.
Recent events (3)
  • — R (S) $10151
  • — C (S) $10151
  • — Z (S) $10151

1926.652 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 25, 2022
Abate by
Jan 31, 2022
Penalty
Initial $145,027 · Current $145,027
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from collapses by an adequate protective system designed in accordance with 1926 Subpart P.  a) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 26, 2021 the employer did not ensure employees working in front of an approximately 20 foot tall shear excavated wall were protected from collapses by the use of an adequate protective system.  The employer allowed the use of 8' x 14' tall steel plate against the excavated wall, which was inadequate for protection against  collapses during retaining wall construction activities, exposing employees to collapse hazards.   b) Jobsite: 700 Ramona Ave, Philadelphia, PA - On or about July 27, 2021 the employer did not ensure employees working in front of an approximately 20 foot tall shear excavated wall were protected from collapses with the use of a protective system. An employee was working within 3 feet of the unprotected wall as it collapsed, thus killing the employee.
Recent events (3)
  • — R (S) $145027
  • — C (W) $145027
  • — Z (W) $145027

View Mayfield Site Contractors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345444087.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.