Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEXAS PRIDE UTILITIES LIMITED LIABILITY CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TEXAS PRIDE UTILITIES LIMITED LIABILITY CORPORATION in 1012 MARTIN ST., HOUSTON, TX 77018 (NAICS 237110). OSHA activity number 345447148.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas Pride Utilities Limited Liability Corporation — free Get an email when a new federal OSHA severe-injury report for Texas Pride Utilities Limited Liability Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1012 MARTIN ST.
City
HOUSTON
State
TX
ZIP
77018
Mailing
725 CARBY RD, HOUSTON, TX 77037
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.651 A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 12, 2021
Abate by
Nov 18, 2021
Penalty
Initial $7,510 · Current $4,506 Reduced
29 CFR  1926.651(a):All surface encumbrances that were located so as to create a hazard to employees were not removed or supported, as necessary, to safeguard employees:  On or about July 27, 2021, at 1012 Martin St., all surface encumbrances had not been supported or removed.
Recent events (2)
  • — I (S) $4506
  • — Z (S) $7510

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 12, 2021
Abate by
Nov 18, 2021
Penalty
Initial $6,008 · Current $0 Reduced
29 CFR  1926.651(j)(2):Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary:  On or about July 27, 2021, at 1012 Martin St., the excavator was not kept at least two feet from the edge of the excavation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6008

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 12, 2021
Abate by
Nov 18, 2021
Penalty
Initial $21,026 · Current $7,510 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  On or about July 27, 2021, at 1012 Martin St., the excavation was not protected from cave-ins by an adequate protective system.
Recent events (2)
  • — I (S) $7510
  • — Z (R) $21026

View Texas Pride Utilities Limited Liability Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345447148.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.