Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HALL MANUFACTURING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HALL MANUFACTURING, LLC in 3706 E. WASHINGTON AVE., NORTH LITTLE ROCK, AR 72114 (NAICS 332999). OSHA activity number 345457212.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hall Manufacturing, LLC — free Get an email when a new federal OSHA severe-injury report for Hall Manufacturing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3706 E. WASHINGTON AVE.
City
NORTH LITTLE ROCK
State
AR
ZIP
72114
Mailing
3706 E. WASHINGTON AVE., NORTH LITTLE ROCK, AR 72114
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
49
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 1 exposed
Issued
Jan 25, 2022
Abate by
Feb 4, 2022
Penalty
Initial $7,252 · Current $5,076 Reduced
29 CFR  1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips, and sparks.  On or about July 27, 2021, at the band saw/drill press work area:  (b)  Employees used a Summit 20 inch Drill Press, Model# 3XHD, Serial#129 to put holes in metal stock.  The drill press was not guarded, exposing employees to making contact with the unguarded chuck and unused portion of the drill bit and being struck by flying metal pieces from the drilling process.
Recent events (2)
  • — I (S) $5076.4
  • — Z (S) $7252

1910.303 B02

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 25, 2022
Abate by
Feb 4, 2022
Penalty
Initial $10,151 · Current $7,106 Reduced
29 CFR  1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  On July 27, 2021, at the band saw work area back wall, employees are exposed to electrical shock and fire hazards while operating equipment plugged into a relocatable power tap or power surge that was plugged into a receptacle. They are not listed or labeled for industrial purposes.
Recent events (2)
  • — I (S) $7105.7
  • — Z (S) $10151

1910.303 G01

Other-than-serious 1 instance 49 exposed
Issued
Jan 25, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  On or about July 27, 2021, in the Band Saw/Drill Press Area of the facility, the electrical switches were blocked by hats, and jackets on the control panel switch.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Hall Manufacturing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345457212.