Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEAK OILFIELD SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEAK OILFIELD SERVICES in 6.5 MILES NW DIRECTION FROM VERHALEN, PECOS, TX 79772 (NAICS 213112). OSHA activity number 345475545.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peak Oilfield Services — free Get an email when a new federal OSHA severe-injury report for Peak Oilfield Services is published. One employer, no account, unsubscribe in one click.
Site address
6.5 MILES NW DIRECTION FROM VERHALEN
City
PECOS
State
TX
ZIP
79772
Mailing
1820 INTERSTATE 35 FRONTAGE ROAD, GAINESVILLE, TX 76240
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
249
Ownership type
A

2 citations on file for this inspection.

1910.244 A02 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $10,533 · Current $10,533
29 CFR  1910.244(a)(2)(i): In the absence of a firm foundation, the base of the jack was not blocked:  On or about August 10, 2021, Citadel Rig #6 location;  the jacks at the front of the Directional Driller's trailer were not blocked on muddy cracked ground. This condition exposed employees to a crush-by hazard.
Recent events (2)
  • — I (O) $10533
  • — Z (S) $10533

1910.29 F04

Other-than-serious 1 instance 1 exposed
Issued
Aug 31, 2021
Abate by
Sep 20, 2021
Penalty
Initial $986 · Current $600 Reduced
29 CFR  1910.29(f)(4): Openings in stair rails. The employer did not ensure that no opening in a stair rail system exceeds 19 inches (48 cm) at its least dimension.  On or about August 10, 2021, Citadel Rig #6 location, the Directional Driller's trailer was not equipped with a mid-rail opening that measured at least 19 inches. This exposed  employees to fall hazards.
Recent events (2)
  • — I (O) $600
  • — Z (O) $986

View Peak Oilfield Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345475545.