Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: URETHANE SERVICES INC.

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of URETHANE SERVICES INC. in EODMU-5 NAVAL BASE GUAM APRA HARBOR, PITI, GU 96915 (NAICS 238310). OSHA activity number 345486153.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Urethane Services INC. — free Get an email when a new federal OSHA severe-injury report for Urethane Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
EODMU-5 NAVAL BASE GUAM APRA HARBOR
City
PITI
State
GU
ZIP
96915
Mailing
STE 147 275G FARENHOLT AVE, TAMUNING, GU 96913
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
3
Ownership type
A

3 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 2, 2021
Penalty
Initial $2,341 · Current $2,341
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use (Construction Reference: 1926.103):  A written respiratory protection program had not been developed and implemented for employees required to wear respirators while performing spray foam insulation work.  Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (S) $2341

1910.134 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 2, 2021
Abate by
Nov 30, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace (Construction Reference: 1926.103):  Medical evaluations were not provided for employees required to wear supplied air hoods and 3M N95 filtering facepiece respirators during spray foam insulation work. Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 2, 2021
Abate by
Nov 30, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter:   Metal Building EODMU-5:  Respirator fit testing was not provided for employees required to wear 3M filtering facepiece respirators during insulation work. Employees were exposed to respiratory hazards.
Recent events (1)
  • — Z (S) $0

View Urethane Services INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345486153.