BOLINGBROOK, IL —
OSHA Inspection: LSC COMMUNICATION MCL LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LSC COMMUNICATION MCL LLC in 1000 WINDHAM PARKWAY, BOLINGBROOK, IL 60440 (NAICS 323117). OSHA activity number 345486567.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LSC COMMUNICATION MCL LLC
- Site address
- 1000 WINDHAM PARKWAY
- City
- BOLINGBROOK
- State
- IL
- ZIP
- 60440
- Mailing
- 1000 WINDHAM PARKWAY, BOLINGBROOK, IL 60440
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323117
- Employees
- 704
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 F01
- Issued
- Jan 19, 2022
- Penalty
- Initial $14,502 · Current $14,502
General-duty citation text
29 CFR 1910.147(f)(1):When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, equipment or component thereof, the sequence of actions. a) On or about August 12, 2021, an employee was exposed to machine hazards associated with moving parts and pinch-points while repairing the Buhrs Pocket, Feeder Model F5, resulting in the partial amputation of the employee's right middle finger. The employer did not implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(f)(1) requirements]. As a result, applicable energy control elements to clear the machine or equipment [(f)(1)(i)], remove employees from the machine or equipment area [(f)(1)(ii)], remove the lockout or tagout devices [(f)(1)(iii)], energize and proceed with testing or positioning [(f)(1)(iv)], and de-energize all systems and reapply energy control measures [(f)(1)(v)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (O) $14502
- — Z (S) $14502
More inspections at LSC Communication MCL LLC