Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CERRO FLOW PRODUCTS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CERRO FLOW PRODUCTS LLC in 8502 MID COUNTY INDUSTRIAL DR., SAINT LOUIS, MO 63114 (NAICS 332996). OSHA activity number 345501910.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cerro Flow Products LLC — free Get an email when a new federal OSHA severe-injury report for Cerro Flow Products LLC is published. One employer, no account, unsubscribe in one click.
Site address
8502 MID COUNTY INDUSTRIAL DR.
City
SAINT LOUIS
State
MO
ZIP
63114
Mailing
8502 MID COUNTY INDUSTRIAL DR., SAINT LOUIS, MO 63114
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
30
Ownership type
A

4 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 21, 2022
Abate by
Feb 16, 2022
Penalty
Initial $6,383 · Current $1,915 Reduced
29 CFR  1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    8502 Mid County Industrial Drive: Employer is exposing employees to amputation hazards where the employees are permitted to use floor fans which are not adequately guarded.   On and about 8/27/2021, employees in the production area were exposed to amputation hazards where the guard openings on floor fans were larger than 1/2 inch.  The blade peripheries of the fans were less than 4 feet above the workplace floor.
Recent events (2)
  • — I (S) $1914.9
  • — Z (S) $6383

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 21, 2022
Abate by
Feb 16, 2022
Penalty
Initial $6,383 · Current $1,915 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  8502 Mid County Industrial Drive, St. Louis, MO 63114, Line 1: Employer is exposing employees to electrical hazards where the employees are permitted to use equipment powered by flexible cord being used as a substitute for fixed wiring. On and about 08/27/21, employees on Liquid Line 1 were exposed to electrical hazards where a flexible cord set was used to supply power to a Belkin relocatable power strip which was in turn used to supply power to electrical equipment such as, but not limited to, an electric scale thereby using the flexible cord set as a substitute for fixed wiring.
Recent events (2)
  • — I (S) $1915.1
  • — Z (S) $6383

1910.1020 G01

Other-than-serious 1 instance 30 exposed
Issued
Jan 21, 2022
Abate by
Feb 16, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1020(g)(1): The employer did not inform current employees upon their first entering in to employment and at least annually thereafter, of the existence, location, and availability of any records covered by 29 CFR 1910:    8502 Mid County Industrial Drive, St. Louis, MO 63114: Employer is not providing required information to employees upon entering employment and annually thereafter about the existence of medical records, the person in charge of the records, and the employees'  rights of access to their own records.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1020 G02

Other-than-serious 1 instance 30 exposed
Issued
Jan 21, 2022
Abate by
Feb 16, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1020(g)(2):The employer did not keep a copy of 29 CFR 1910.1020 and its appendices at the workplace, and/or, upon request, make copies readily available to employees:  8502 Mid County Industrial Drive, St. Louis, MO 63114: Employees were not provided a copy of the regulation as required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cerro Flow Products LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345501910.