WHEELING, IL —
OSHA Inspection: WAUKEGAN ROOFING COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WAUKEGAN ROOFING COMPANY, INC. in 395 E. DUNDEE ROAD, WHEELING, IL 60090 (NAICS 238160). OSHA activity number 345512784.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAUKEGAN ROOFING COMPANY, INC.
- Site address
- 395 E. DUNDEE ROAD
- City
- WHEELING
- State
- IL
- ZIP
- 60090
- Mailing
- 250-252 CHADDICK DRIVE, WHEELING, IL 60090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B10
- Issued
- Dec 17, 2021
- Penalty
- Initial $9,557 · Current $13,000
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system; a) Front Roof Edge - On or about September 1, 2021, employees were exposed to the hazard of falling approximately 27 feet from an upper roof deck to the ground while performing roofing work along the edge of the roof without the use of fall protection or a safety monitor. b) North Roof Edge - On or about September 1, 2021, employees were exposed to the hazard of falling approximately 13 feet from an upper roof deck to a lower roof deck while performing roofing work along the edge of the roof without the use of fall protection or a safety monitor. c) South Roof Edge - On or about September 1, 2021, employees were exposed to the hazard of falling approximately 13 feet from an upper roof deck to a lower roof deck while performing roofing work along the edge of the roof without the use of fall protection or a safety monitor. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $13000
- — Z (S) $9557
1926.502 F01 III
- Issued
- Dec 17, 2021
- Penalty
- Initial $6,827 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: a) Between the Upper Roof Deck and Lower Roof Deck (North End) - On or about September 1, 2021, employees were exposed to the hazard of falling approximately 13 feet where warning lines were not used to create access paths connecting the work area to the point of access along the roof edge. b) Between the Lower Roof Deck and Ground (North End Rear)- On or about September 1, 2021, employees were exposed to the hazard of falling approximately 14 feet where warning lines were not used to create access paths connecting the work area to the point of access along the roof edge. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $6827
1926.502 F02 II
- Issued
- Dec 17, 2021
- Penalty
- Initial $9,557 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(f)(2)(ii): Warning line systems were not rigged and supported in such a way that its lowest point (including sag) was not less than 34 inches from the walking/working surface: a) North Roof Edge - On or about September 1, 2021, warning lines along the roof edge was not rigged and supported to prevent sagging below 34 inches. b) South Roof Edge - On or about September 1, 2021, warning lines along the roof edge was not rigged and supported to prevent sagging below 34 inches. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $9557
1926.503 B01
- Issued
- Dec 17, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record: a) On or about September 1, 2021, the employer did not prepare written certification records related to employee fall protection training. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Waukegan Roofing Company, INC.