Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D&M WELDING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D&M WELDING, INC. in 6 WELDING WAY, FAIRMONT, WV 26554 (NAICS 332322). OSHA activity number 345522924.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D&M Welding, INC. — free Get an email when a new federal OSHA severe-injury report for D&M Welding, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
D&M WELDING, INC.
Site address
6 WELDING WAY
City
FAIRMONT
State
WV
ZIP
26554
Mailing
PO BOX 2073, FAIRMONT, WV 26554
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2021
Penalty
Initial $3,121 · Current $3,121
29 CFR  1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a)  Machine Shop:  On September 2, 2021 and times prior, employees operated a Wilton pedestal abrasive wheel grinder that had an opening of one inch between the grinding wheel and the adjustable tongue guard.
Recent events (1)
  • — Z (S) $3121

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 22, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:  (a) Facility Wide:   On September 2, 2021 and times prior, the employer did not conduct an annual periodic inspection between an inspector and authorized employee to ensure that the employee(s) followed the energy control procedures for the, but not limited to, press brake, plate roller and the CNC plasma arc.
Recent events (1)
  • — Z (O) $0

View D&M Welding, INC.'s full OSHA safety record →