FAIRMONT, WV —
OSHA Inspection: D&M WELDING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D&M WELDING, INC. in 6 WELDING WAY, FAIRMONT, WV 26554 (NAICS 332322). OSHA activity number 345522924.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D&M WELDING, INC.
- Site address
- 6 WELDING WAY
- City
- FAIRMONT
- State
- WV
- ZIP
- 26554
- Mailing
- PO BOX 2073, FAIRMONT, WV 26554
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.215 B09
- Issued
- Sep 22, 2021
- Penalty
- Initial $3,121 · Current $3,121
General-duty citation text
29 CFR 1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Machine Shop: On September 2, 2021 and times prior, employees operated a Wilton pedestal abrasive wheel grinder that had an opening of one inch between the grinding wheel and the adjustable tongue guard.
Recent events (1)
- — Z (S) $3121
1910.147 C06 I
- Issued
- Sep 22, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: (a) Facility Wide: On September 2, 2021 and times prior, the employer did not conduct an annual periodic inspection between an inspector and authorized employee to ensure that the employee(s) followed the energy control procedures for the, but not limited to, press brake, plate roller and the CNC plasma arc.
Recent events (1)
- — Z (O) $0
More inspections at D&M Welding, INC.
View D&M Welding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345522924.