On , OSHA opened a complaint safety inspection of HNS MANAGEMENT CO., INC. in 100 LEIBERT STREET, HARTFORD, CT 06120 (NAICS 485210). OSHA activity number 345533541.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HNS Management CO., INC. — free Get an email when a new federal OSHA severe-injury report for HNS Management CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 LEIBERT STREET
City
HARTFORD
State
CT
ZIP
06120
Mailing
P.O. BOX 66, HARTFORD, CT 06141
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
485210
Employees
729
Ownership type
A

8 citations on file for this inspection.

1910.28 B03 I

Serious Gravity 5 13 instances 2 exposed
Issued
Dec 28, 2021
Abate by
Jun 15, 2022
Penalty
Initial $9,119 · Current $6,000 Reduced
29 CFR  1910.28(b)(3)(i):  The employer did not ensure that each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following methods listed in 29 CFR 1910.28(b)(3)(i)(A)-(D):  Roof:  On, or about, September 20, 2021, an employee was exposed to potential fall hazards while accompanying a HVAC contractor who was performing preventive maintenance on roof mounted equipment.  The company had provided free-standing railings or skylight screens for only some of the skylight openings on the roof, leaving the majority of the skylights unprotected.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $9119

1910.146 C03

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 28, 2021
Abate by
Apr 15, 2022
Penalty
Initial $5,471 · Current $3,500 Reduced
29 CFR  1910.146(c)(3):  When the employer decided that its employees would not enter permit spaces, the employer did not comply with 29 CFR 1910.146(c)(1), 29 CFR 1910.146(c)(2), 29 CFR 1910.146(c)(6), and 29 CFR 1910.146(c)(8):  Company:  On, or about, November 9, 2021, the employer had not conducted an assessment to identify permit required confined spaces, had not marked permit required confined spaces and had not developed a program to inform contractors of the hazards associated with confined spaces.  In addition, the employees of the company accompanied contractors who worked in confined spaces and assisted with removing/replacing covers to facilitate work in confined spaces.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5471

1910.147 C04 I

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 28, 2021
Abate by
Jun 15, 2022
Penalty
Initial $7,295 · Current $3,500 Reduced
29 CFR  1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Company:  On, or about, November 9, 2021, the employer had not developed and implemented a written lockout/tagout program that included specific written procedures for multiple energy source equipment in the facility.  Equipment in the facility included, but was not limited to, hydraulic lifts, bus washing equipment, HVAC units, boilers, dust collection equipment, spray finishing equipment, drainage/sewage collection pits with associated pumps/piping, metal working equipment and abrasive blasting equipment.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7295

1910.212 A03 II

Serious Gravity 5 3 instances 8 exposed
Issued
Dec 28, 2021
Abate by
Apr 15, 2022
Penalty
Initial $9,119 · Current $5,000 Reduced
29 CFR  1910.212(a)(3)(ii):  Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Body Shop:  On, or about, September 16, 2021, the following machines were not provided with safeguarding:  A.	W.A. Whitney hydraulic shear. B.	W.A. Whitney coper-notcher-bender. C.	Baileigh hydraulic shear, both the point of operation and hold down.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9119

1910.303 G01 I A

Other-than-serious Gravity 1 2 instances 9 exposed
Issued
Dec 28, 2021
Abate by
Feb 15, 2022
Penalty
Initial $5,471 · Current $2,000 Reduced
29 CFR  1910.303(g)(1)(i)(A):  For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  A.  Bay 41:  On, or about, September 16, 2021, Machine 11, a Baldor pedestal grinder, was anchored to the floor in front of the Furnas control box provided for the dust collection system.  B.  Bay 30:  On, or about, September 16, 2021, Machine 10, a Baldor pedestal grinder, was anchored to the floor in front of the Furnas control box provided for the dust collection system.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $5471

1910.303 G01 II

Other-than-serious Gravity 1 4 instances 9 exposed
Issued
Dec 28, 2021
Abate by
Feb 15, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii):  The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  On, or about, September 16, 2021, items were stored in front of electrical equipment in the following areas:  A.	Body Shop:  Vehicle components were stored in front of the disconnect for the sandblaster.  B.	Mechanic Bays:  A rolling tool box was stored in the working space of the Westinghouse motor control center, MCC-MSP-9.  Also, a hose and electrical cord were hanging from the right side and a battery charging shelf had been installed on the left side of the enclosure.  C.	Fabrication Shop:  Two MIG welders were stored in front of the disconnect for the drill press receptacle.  D.	Generator Room (M148):  Throughout the room, items such as, but not limited to, portable lights, boxes, a wet/dry vacuum, a ladder, a conduit bender, a chair and plastic saw horses were stored in front of electrical panels.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G01 IV A

Other-than-serious 2 instances 2 exposed
Issued
Dec 28, 2021
Abate by
Feb 15, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Bay 30:  On, or about, September 30, 2021, a yellow drop light with a receptacle provided at the lamp was used to energize a refrigerator and a green extension cord was used to energize a battery charger.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 II

Other-than-serious 1 instance 4 exposed
Issued
Dec 28, 2021
Abate by
Feb 15, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii):  There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  Body Shop:  On, or about September 16, 2021, the power cord provided for the W.A. Whitney portable fabrication cart was damaged.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0