Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELITE BROTHERS CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELITE BROTHERS CONSTRUCTION LLC in 820 BLOOMFIELD AVE, CLIFTON, NJ 07012 (NAICS 238140). OSHA activity number 345557938.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elite Brothers Construction LLC — free Get an email when a new federal OSHA severe-injury report for Elite Brothers Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
820 BLOOMFIELD AVE
City
CLIFTON
State
NJ
ZIP
07012
Mailing
432 E 24TH STREET, PATERSON, NJ 07514
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 18, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  a)  Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not fully planked, on or about 10/1/21.  b)  Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not fully planked, on or about 10/6/21.
Recent events (1)
  • — Z (S) $2486

1926.451 C02

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 18, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:   a)  Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not supported on base plates, on or about 10/1/21.  b)  Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not supported on base plates, on or about 10/6/21.
Recent events (1)
  • — Z (S) $2486

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.   a)  Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that had no safe means of access, on or about 10/1/21.
Recent events (1)
  • — Z (S) $2486

1926.451 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 18, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR  1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.   The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:*Insulated Lines   less than 300 volts.  3 feet (0.91 m) Insulated Lines   300 volts to 50 kv.  10 feet (3.1 m)   Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines.  a)  Exterior of Building - Scaffold: Employees were exposed to electric hazards while engaged in masonry activities from a welded frame scaffold  platform that was less  than 1 foot from an energized  4KVA primary line, on or about 10/1/21
Recent events (1)
  • — Z (S) $3108

View Elite Brothers Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345557938.