CLIFTON, NJ —
OSHA Inspection: ELITE BROTHERS CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ELITE BROTHERS CONSTRUCTION LLC in 820 BLOOMFIELD AVE, CLIFTON, NJ 07012 (NAICS 238140). OSHA activity number 345557938.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELITE BROTHERS CONSTRUCTION LLC
- Site address
- 820 BLOOMFIELD AVE
- City
- CLIFTON
- State
- NJ
- ZIP
- 07012
- Mailing
- 432 E 24TH STREET, PATERSON, NJ 07514
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Mar 18, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not fully planked, on or about 10/1/21. b) Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not fully planked, on or about 10/6/21.
Recent events (1)
- — Z (S) $2486
1926.451 C02
- Issued
- Mar 18, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not supported on base plates, on or about 10/1/21. b) Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that was not supported on base plates, on or about 10/6/21.
Recent events (1)
- — Z (S) $2486
1926.451 E01
- Issued
- Mar 18, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Exterior of Building - Scaffold: Employees were exposed to fall hazards of approximately 6 feet while engaged in masonry activities from a welded frame scaffold platform that had no safe means of access, on or about 10/1/21.
Recent events (1)
- — Z (S) $2486
1926.451 F06
- Issued
- Mar 18, 2022
- Penalty
- Initial $3,108 · Current $3,108
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:*Insulated Lines less than 300 volts. 3 feet (0.91 m) Insulated Lines 300 volts to 50 kv. 10 feet (3.1 m) Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines. a) Exterior of Building - Scaffold: Employees were exposed to electric hazards while engaged in masonry activities from a welded frame scaffold platform that was less than 1 foot from an energized 4KVA primary line, on or about 10/1/21
Recent events (1)
- — Z (S) $3108
More inspections at Elite Brothers Construction LLC
View Elite Brothers Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345557938.