Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRO-MECHANICAL PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELECTRO-MECHANICAL PRODUCTS, INC. in 897 TABOR ST., LAKEWOOD, CO 80401 (NAICS 335999). OSHA activity number 345564769.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electro-Mechanical Products, INC. — free Get an email when a new federal OSHA severe-injury report for Electro-Mechanical Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
897 TABOR ST.
City
LAKEWOOD
State
CO
ZIP
80401
Mailing
897 TABOR ST., LAKEWOOD, CO 80401
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
170
Ownership type
A

1 citation on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 2, 2021
Penalty
Initial $5,969 · Current $3,580 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Electro-Mechanical Products, Inc. at 897 Tabor St. Lakewood, CO 80401. On or before 10/6/21 the employer did not protect employees from injury in that the Amada To-50EC horizontal bandsaw had 2.5 inches of the unused portion of the blade exposed. This condition exposed employees to laceration and amputation hazards.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (S) $3580
  • — Z (S) $5969

View Electro-Mechanical Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345564769.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.