OSHA Inspection: MCCLINTOCK CABINETS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MCCLINTOCK CABINETS, INC. in N3151 STATE ROAD 47, APPLETON, WI 54913 (NAICS 337110). OSHA activity number 345572366.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mcclintock Cabinets, INC. — free Get an email when a new federal OSHA severe-injury report for Mcclintock Cabinets, INC. is published. One employer, no account, unsubscribe in one click.
Site address
N3151 STATE ROAD 47
City
APPLETON
State
WI
ZIP
54913
Mailing
N3151 STATE ROAD 47, APPLETON, WI 54913
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
6
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 1, 2022
Abate by
Aug 15, 2023
Penalty
Initial $3,108 · Current $1,554 Reduced

Hazardous substances M102

OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working near and indoor dust collectors handling combustible wood dust generated by several upstream processes were exposed to wood dust fire hazards presented by the indoor dust collection systems and its associated upstream equipment:  On or about October 20, 2021, at a facility located at N3151 State Road 47, Appleton, WI 54913; an indoor cartridge filter media dust collector (Northtech, Model NT-DC2500RAL-ACS, S/N 072808) with positive pressure air-material inlet and three cartridge media filters was used to collect combustible wood dust fines from a wide belt sanding machine (Butfering Model SWT 134 RRC, S/N 0411492649). The dust collector was used to collect wood dust from equipment recognized as being capable of producing frequent sparks and was located near normally occupied areas. Employees were exposed to combustible wood dust hazards including flames and hazardous byproducts (smoke, toxic gases, etc.) resulting from this indoor collection system setup.
Recent events (2)
  • — I (S) $1554
  • — Z (S) $3108

1910.132 D01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2022
Abate by
Apr 29, 2022
Penalty
Initial $2,486 · Current $1,243 Reduced
29 CFR  1910.132(d)(1)(i):  The employer shall select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment:  At a facility located at N3151 State Road 47, Appleton, WI 54913; the employer did not require employees to wear eye protection when employees were exposed to injurious eye hazards such as, but not limited to, flying particulate generated by powered equipment (e.g. saws, sanders and routers).
Recent events (2)
  • — I (S) $1243
  • — Z (S) $2486

1910.132 D02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2022
Abate by
Apr 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2):  The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment:  At a facility located at N3151 State Road 47, Appleton, WI 54913; the employer did not verify through written certification, that a workplace hazard assessment for the use of personal protective equipment had been conducted when employees were exposed to injurious eye hazards such as, but not limited to, flying particulate generated by powered equipment (e.g. saws, sanders and routers).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.133 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2022
Abate by
Apr 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.133(a)(1):  The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:   At a facility located at N3151 State Road 47, Appleton, WI 54913; the employer did ensure that each affected employee used appropriate eye protection when employees were exposed to injurious eye hazards such as, but not limited to, flying particulate generated by powered equipment (e.g. saws, sanders and routers).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.133 A02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2022
Abate by
Apr 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.133(a)(2):  The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable:   At a facility located at N3151 State Road 47, Appleton, WI 54913; the employer did ensure that each affected employee used eye protection that provided side protection when employees were exposed to injurious eye hazards such as flying particulate generated by powered equipment (e.g. saws, sanders and routers).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 1, 2022
Penalty
Initial $1,865 · Current $931 Reduced
29 CFR  1910.134(e)(1):  The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator:  On or about October 20, 2021, at a facility located at N3151 State Road 47, Appleton, WI 54913; the employer did not provide a medical evaluation to determine an employee's ability to use a tight-fitting half-face negative pressure air purifying respirator (3M Model 7503 with organic vapor cartridge) prior to the employee being fit tested and required to use the respirator during spray application of stains and finishes.
Recent events (2)
  • — I (S) $931
  • — Z (S) $1865

View Mcclintock Cabinets, INC.'s full OSHA safety record →