PITTSBURGH, PA —
OSHA Inspection: J M DAUGHERTY INDUSTRIES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J M DAUGHERTY INDUSTRIES in 4785 GIESE DRIVE, PITTSBURGH, PA 15227 (NAICS 237110). OSHA activity number 345579023.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J M DAUGHERTY INDUSTRIES
- Site address
- 4785 GIESE DRIVE
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15227
- Mailing
- 103 FREEDOM ROAD, LAWRENCE, PA 15055
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 48
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Apr 1, 2022
- Abate by
- Apr 13, 2022
- Penalty
- Initial $8,702 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 14, 2021, an employee was working near a trench box as the box was being lifted by an excavator. The employee was not wearing a hard hat. The employee received a head injury when a part of the trench box fell off and struck the employee on the head. b) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 13, 2021, an employee who was not wearing a hard hat was working at the bottom of a trench that was approximately 9 feet 8 inches in depth. The employee was exposed to struck-by hazards from debris falling into the trench from above. c) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 14, 2021, an employee who was not wearing a hard hat was working at the bottom of a trench that was approximately 9 feet 8 inches in depth. The employee was exposed to struck-by hazards from debris falling into the trench from above.
Recent events (3)
- — F (O) $3000
- — C (S) $8702
- — Z (S) $8702
1926.652 E02 I
- Issued
- Apr 1, 2022
- Penalty
- Initial $4,351 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.652(e)(2)(i): Excavation of material to a level no greater than 2 feet (.61m) below the bottom of the members of the support system was allowed when there were indications while the trench was open of a possible loss of soil from behind or below the bottom of the support system: a) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 13, 2021, an employee was working in a trench that was approximately 9 feet 8 inches in depth with vertical sidewalls. Speed Shore brand hydraulic shoring with plywood sheeting was being used to shore a portion of the trench near where the ladder was located. The bottom of the plywood sheeting on the north side of the trench set approximately 3 feet 3 inches above the bottom of the trench making it possible for a loss of soil from behind or below the bottom of the support system. b) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 14, 2021, an employee was working in a trench that was approximately 9 feet 8 inches in depth with vertical sidewalls. Speed Shore brand hydraulic shoring with plywood sheeting was being used to shore a portion of the trench near where the ladder was located. The bottom of the plywood sheeting on the north side of the trench set approximately 3 feet 3 inches above the bottom of the trench making it possible for a loss of soil from behind or below the bottom of the support system.
Recent events (3)
- — F (O) $3000
- — C (S) $4351
- — Z (S) $4351
1926.652 C02 I
- Issued
- Apr 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: (a) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 13, 2021, Speed Shore brand aluminum hydraulic shoring was being used in a trench that was approximately 9 feet 8 inches in depth with vertical sidewalls. The support system was not installed in a manner that was in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer. (b) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 14, 2021, Speed Shore brand aluminum hydraulic shoring was being used in a trench that was approximately 9 feet 8 inches in depth with vertical sidewalls. The support system was not installed in a manner that was in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Apr 1, 2022
- Penalty
- Initial $20,303 · Current $6,000 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): (a) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 13, 2021, employees were working in a trench that was approximately 9 feet 8 inches in depth with vertical sidewalls while not protected from cave-ins. Employees were exposed to a crushed-by hazard while working in areas of the trench where there was no cave-in protection. Also, Speed Short brand hydraulic shoring being used to shore part of the trench was not being used in a manner consistent with the manufacturer's tabulated data. (b) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 14, 2021, employees were working in a trench that was approximately 9 feet 8 inches in depth with vertical sidewalls while not protected from cave-ins. Employees were exposed to a crushed-by hazard while working in areas of the trench where there was no cave-in protection. Also, Speed Short brand hydraulic shoring being used to shore part of the trench was not being used in a manner consistent with the manufacturer's tabulated data. J M Daugherty Industries dba Mister Sewer was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.652(a)(1), which was contained in OSHA inspection number 1522776 citation number 1 item number 1a, and was affirmed as a final order on April 26, 2021, with respect to a workplace located at 404 Union Street, Pittsburgh, PA 15205.
Recent events (3)
- — F (O) $6000
- — C (R) $20303
- — Z (R) $20303
1926.651 K02
- Issued
- Apr 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: a) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 13, 2021, the competent person did not prevent employees from working at the bottom of a trench that was approximately 9 feet 8 inches deep with vertical sidewalls until necessary precautions were taken to ensure the safety of the employees. Employees were exposed to a cave-in hazard while working in areas of the trench outside of the hydraulic shores. A ladder used to access the bottom of the trench was located along an exposed vertical wall that was not shored or sloped. The hydraulic shoring system being used was not installed in a manner consistent with the manufacturer's tabulated data. a) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On or about October 14, 2021, the competent person did not prevent employees from working at the bottom of a trench that was approximately 9 feet 8 inches deep with vertical sidewalls until necessary precautions were taken to ensure the safety of the employees. Employees were exposed to a cave-in hazard while working in areas of the trench outside of the hydraulic shores. A ladder used to access the bottom of the trench was located along an exposed vertical wall that was not shored or sloped. The hydraulic shoring system being used was not installed in a manner consistent with the manufacturer's tabulated data. J M Daugherty Industries dba Mister Sewer was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.651(k)(2), which was contained in OSHA inspection number 1522776 citation number 1 item number 1b, and was affirmed as a final order on April 26, 2021, with respect to a workplace located at 404 Union Street, Pittsburgh, PA 15205.
Recent events (3)
- — F (R) $0
- — C (R) $0
- — Z (R) $0
1926.652 C02 III
- Issued
- Apr 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations were not in written form at the jobsite during construction of the protective system: (a) Jobsite, 4785 Giese Drive, Pittsburgh, PA 15227: On and before October 14, 2021, a Speed Shore brand hydraulic trench shoring system with plywood sheeting was being used to shore a portion of a trench that was approximately 9 feet 8 inches in depth with vertical sidewalls. The employer did not maintain a copy of the manufacturer's tabulated data for the shoring system at the jobsite.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at J M Daugherty Industries
View J M Daugherty Industries's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345579023.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.