CENTERVILLE, OH —
OSHA Inspection: JAIME GONZALEZ
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of JAIME GONZALEZ in 2221 COLD STREAM DR., CENTERVILLE, OH 45458 (NAICS 238130). OSHA activity number 345579890.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JAIME GONZALEZ
- Site address
- 2221 COLD STREAM DR.
- City
- CENTERVILLE
- State
- OH
- ZIP
- 45458
- Mailing
- 1622 MERIMINE AVE, DAYTON, OH 45410
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 10, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a) On October 1, 2021, located on the north side of a residential roof structure, an employee was exposed to a fall hazard not utilizing any fall protection system while standing at the edge of the low pitch roof installing sheathing. Potential fall height measured to be 11'-7" with a roof pitch of 2/12.
Recent events (1)
- — Z (S) $4096
1926.502 A02
- Issued
- Nov 10, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection: (A) Guardrail systems; (B) Safety net systems; or (C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems. a) On October 1, 2021, located on the north side of a residential roof structure, an employee was exposed to a fall hazard installing sheathing at the edge of the roof in that the employer failed to install a fall protection system before the employee performed the work. Potential fall height measured to be 11'-7" with a roof pitch of 2/12.
Recent events (1)
- — Z (S) $4096
1926.503 A01
- Issued
- Nov 10, 2021
- Abate by
- Dec 30, 2021
- Penalty
- Initial $4,096 · Current $4,096
General-duty citation text
29 CFR 1926.503(a)(1):The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. a) On October 1, 2021, located on the north side of a residential roof, an employee was exposed to a fall hazard installing sheathing at the roof edge that had not been trained by the employer to recognize the hazards of falling and the procedures to be followed to minimize these hazards. Potential fall height measured to be 11'-7" with a roof pitch of 2 /12.
Recent events (1)
- — Z (S) $4096
More inspections at Jaime Gonzalez
View Jaime Gonzalez's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345579890.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.