Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RE MARBLE & GRANITE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RE MARBLE & GRANITE, INC. in 139 NEW HAMPSHIRE ROUTE 101, TEMPLE, NH 03084 (NAICS 327991). OSHA activity number 345588677.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RE Marble & Granite, INC. — free Get an email when a new federal OSHA severe-injury report for RE Marble & Granite, INC. is published. One employer, no account, unsubscribe in one click.
Site address
139 NEW HAMPSHIRE ROUTE 101
City
TEMPLE
State
NH
ZIP
03084
Mailing
139 NEW HAMPSHIRE ROUTE 101, TEMPLE, NH 03084
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
12
Ownership type
A

12 citations on file for this inspection.

1910.178 A04

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $4,144 · Current $2,000 Reduced
1910.178(a)(4): Modifications and additions which affected the capacity and safe operation were performed by the customer or user without manufacturers prior written approval.  Capacity, operation, and maintenance instruction plates, tags, and decals were not changed accordingly:      Fabrication Shop, Hyster forklift model H80XM, Serial number L005V02943B - On or about October 20, 2021, modifications and additions were made to the forklift without permission from the manufacturer and data tags or decals were not changed accordingly. The forklift was equipped with a G-Force Fabrication Inc. boom extension marked as serial number 090404 (utilized at approximately 9 feet) and slab clamp that affected the capacity and safe operation while it was used to lift and transport stone slabs.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4144

1910.178 P01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $4,144 · Current $0 Reduced
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s).  Fabrication Shop, Hyster forklift model H80XM, Serial number L005V02943B - On or about October 20, 2021,  the G-Force Fabrication Inc. boom extension, serial number 090404, was used to lift, transport, and lower stone slab loads while the boom was not attached to the forklift with it's securing chain.  Additionally, the load end of the boom was excessively worn where the slab lifting clamp was attached.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4144

1910.178 Q07

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(7): Industrial trucks were not examined at least daily before being placed in service.               Fabrication Shop, Hyster forklift model H80XM, Serial number L005V02943B - On or about October 20, 2021,  the forklift was not inspected to ensure safe and adequate attachment of the boom extension to the forklift and to ensure appropriate markings (tags, plates or decals) were located on the forklift to identify the capacity and other necessary manufacturer information.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $4,144 · Current $2,000 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a.) Fabrication shop -  On or about October 20, 2021, the cutting blade on the GMM Eura 35A bridge saw was not guarded to protect the operator and other employees from the point of operation, rotating parts and flying debris.  b.) Fabrication shop - On or about October 20, 2021, the cutting blade on the  Fusion 4045 CNC slab saw was not guarded to protect the operator and other employees from the point of operation, rotating parts and flying debris.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4144

1910.334 A02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $4,144 · Current $2,000 Reduced
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  Fabrication Shop,  Marmo Elettromeccanica Master 3500 Router - On or about October 20, 2021, the router had a damaged power cord that could have exposed an employee to injury and was not removed from service where the rubber boot on the housing of the router was torn, the outer insulation was pulled out and the internal insulated conductors were exposed.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4144

1910.1200 E01

Serious Gravity 5 1 instance 7 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $4,144 · Current $2,000 Reduced
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Fabrication Shop - On or about October 20, 2021, the employer had not developed or implemented a written hazard communication program where employees were exposed to various chemicals with specific target organ effects to include the eyes, skin, respiratory system and digestive system with two of the chemicals being carcinogens.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4144

1910.1200 F06 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 11, 2022
Abate by
Apr 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with product identifier and words, pictures, symbols, or combination thereof, which provided at least general information regarding the hazards of the chemicals:  Fabrication Shop, polishing area work bench - On or about October 20, 2021, the employer did not ensure each container of hazardous chemicals in the workplace was labeled for its contents where there was a spray bottle containing Acetone which had no labeling.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 11, 2022
Abate by
Apr 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(1):  The employer did not have a safety data sheet in the workplace for each hazardous chemical which they use:  Fabrication Shop - On or about October 20, 2021, the employer did not maintain safety data sheets for hazardous chemicals used by employees in the workplace which have serious physical and health hazards according to their manufacturers, including, but not limited to:  Akemi-Platinum; an eye and skin irritant, carcinogen, causes damage to hearing through prolonged or repeated exposure and category 3 flammable.  Xylene; a serious eye and skin irritant, category 2 carcinogen, may cause cyanosis, blood serum changes, central nervous system damage and narcosis.  Integra Adhesive; a severe eye irritant, respiratory irritant that may cause nervous system depression, and may cause liver & kidney injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 11, 2022
Abate by
Apr 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work areas at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.   Fabrication Shop - On or about October 20, 2021, employees who use chemicals daily were not trained in the hazards and potential health effects of those chemicals which according to safety data sheets include, but are not limited to:   Akemi-Platinum; an eye and skin irritant, carcinogen, causes damage to hearing through prolonged or repeated exposure and category 3 flammable.  Xylene; a serious eye and skin irritant, category 2 carcinogen, may cause cyanosis, blood serum changes, central nervous system damage and narcosis.  Integra Adhesive; a severe eye irritant, respiratory irritant that may cause nervous system depression, and may cause liver & kidney injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1053 J01

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1053(j)(1): The employer did not ensure that each employee was trained in accordance with the provisions of HCS and paragraph (j)(3) of this section:  Fabrication shop  On or about November 1, 2021,  the employer did not train employees on the hazards associated with exposure to  respirable crystalline silica where employees were cutting, grinding, and polishing granite, quartz, and quartzite, that generate  respirable crystalline silica dust.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.169 B03 IV

Other-than-serious 1 instance 4 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.169(b)(3)(iv): Safety valve(s) on compressed air receiver(s) were not tested at frequently regular intervals to determine if they were in good operating condition:  Fabrication Shop, Silvan Industries Inc. compressed air tank (Serial #322A25) & Steel Fab II compressed air tank (Part #A10053) - On or about October 20, 2021, the employer did not ensure that the safety valves on two compressed air tanks were tested at frequently regular intervals to determine if they were in good operating condition.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 2 instances 3 exposed
Issued
Apr 11, 2022
Abate by
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  a.) Fabrication shop -  On or about October 20, 2021, access to the electrical disconnect was not provided and maintained for the GMM Eura 35A bridge saw to permit ready and safe operation where there was a snow blower being stored in front of the disconnect, preventing access to it.  b.) Fabrication shop -  On or about October 20, 2021, access to the electrical disconnect was not provided and maintained for the Fusion 4045 CNC slab saw to permit ready and safe operation where there was plate steel stacked on the floor of the pathway and impeding access to it.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View RE Marble & Granite, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345588677.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.