HUTCHINSON, KS —
OSHA Inspection: SUPERIOR BOILER LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUPERIOR BOILER LLC in 714 COREY ROAD, HUTCHINSON, KS 67501 (NAICS 332410). OSHA activity number 345588925.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPERIOR BOILER LLC
- Site address
- 714 COREY ROAD
- City
- HUTCHINSON
- State
- KS
- ZIP
- 67501
- Mailing
- 3524 EAST 4TH AVENUE, HUTCHINSON, KS 67501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332410
- Employees
- 43
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 19, 2021
- Abate by
- Dec 16, 2021
- Penalty
- Initial $9,557 · Current $5,256 Reduced
General-duty citation text
1910.212(a)(1) One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Employee engaged in production activities were exposed to amputation hazards in the employer permitted the use of a press brake without the use of two hand control function, which caused an amputation to an employee at the point of operation.
Recent events (2)
- — I (S) $5256.35
- — Z (S) $9557
1910.305 G01 IV A
- Issued
- Nov 19, 2021
- Abate by
- Dec 16, 2021
- Penalty
- Initial $5,461 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: At the Fabrication Shop, employee(s) engaged in production activities were exposed to struck-by, fire and electrical shock hazards in that the flexible cord used to supply power to a Dayton 1/2 ton hoist was used in lieu of fixed wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $5461
1910.305 G01 IV D
- Issued
- Nov 19, 2021
- Abate by
- Dec 16, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D):Flexible cords and cables were attached to building surfaces: At the Fabrication Shop, employees engaged in production activities were exposed to fire and electrical shock hazards in that a 110 volt flexible cord suppling power to a Dayton 1/2 ton hoist was secured to the building surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332410)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345588925.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.