Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR BOILER LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUPERIOR BOILER LLC in 714 COREY ROAD, HUTCHINSON, KS 67501 (NAICS 332410). OSHA activity number 345588925.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Boiler LLC — free Get an email when a new federal OSHA severe-injury report for Superior Boiler LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SUPERIOR BOILER LLC
Site address
714 COREY ROAD
City
HUTCHINSON
State
KS
ZIP
67501
Mailing
3524 EAST 4TH AVENUE, HUTCHINSON, KS 67501
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
43
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 19, 2021
Abate by
Dec 16, 2021
Penalty
Initial $9,557 · Current $5,256 Reduced
1910.212(a)(1)  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Employee engaged in production activities were exposed to amputation hazards in the employer permitted the use of a press brake without the use of two hand control function, which caused an amputation to an employee at the point of operation.
Recent events (2)
  • — I (S) $5256.35
  • — Z (S) $9557

1910.305 G01 IV A

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 19, 2021
Abate by
Dec 16, 2021
Penalty
Initial $5,461 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  At the Fabrication Shop, employee(s) engaged in production activities were exposed to struck-by, fire and electrical shock hazards in that the flexible cord used to supply power to a Dayton 1/2 ton hoist was used in lieu of fixed wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5461

1910.305 G01 IV D

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Nov 19, 2021
Abate by
Dec 16, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(D):Flexible cords and cables were attached to building surfaces:  At the Fabrication Shop, employees engaged in production activities were exposed to fire and electrical shock hazards in that a 110 volt flexible cord suppling power to a Dayton 1/2 ton hoist was secured to the building surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345588925.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.