Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACME FOUNDRY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACME FOUNDRY, INC. in 1502 SPRUCE ST, COFFEYVILLE, KS 67337 (NAICS 331511). OSHA activity number 345591622.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acme Foundry, INC. — free Get an email when a new federal OSHA severe-injury report for Acme Foundry, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ACME FOUNDRY, INC.
Site address
1502 SPRUCE ST
City
COFFEYVILLE
State
KS
ZIP
67337
Mailing
P.O. BOX 908, COFFEYVILLE, KS 67337
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
300
Ownership type
A

1 citation on file for this inspection.

1910.101 B

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Feb 16, 2022
Abate by
Mar 15, 2022
Penalty
Initial $6,215 · Current $4,351 Reduced
29 CFR  1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:     Employees were exposed to injury from fire and explosion or a projectile hazards. Employees operating forklifts engaged in changing propane tanks were exposed to fire and explosion or projectile hazards in that compressed gas cylinders, that were not in use, were not secured to prevent damage in accordance with Compressed Gas Association Pamphlet P-1-1965. Three propane gas cylinders located outside, northside of the building, right end of the propane storage rack were stored unsecured.
Recent events (2)
  • — I (O) $4350.5
  • — Z (S) $6215

View Acme Foundry, INC.'s full OSHA safety record →