Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C PACIFIC CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C PACIFIC CORPORATION in SAN VICENTE, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 345610356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C Pacific Corporation — free Get an email when a new federal OSHA severe-injury report for C Pacific Corporation is published. One employer, no account, unsubscribe in one click.
Site address
SAN VICENTE
City
SAIPAN
State
MP
ZIP
96950
Mailing
P.O. BOX 503984, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
45
Ownership type
A

6 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 27, 2022
Abate by
Feb 8, 2022
Penalty
Initial $4,351 · Current $2,685 Reduced
29 CFR  1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  Southwest corner  of the house: The electrical receptacle box designed to be installed in a wall was used on the end of an extension cord. Employees were exposed to fire and electrical hazards
Recent events (3)
  • — F (S) $2685
  • — C (S) $4351
  • — Z (S) $4351

1926.405 J01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 27, 2022
Abate by
Feb 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:   Southwest corner  of the house: The cover on the receptacle box used to power the saw was missing, exposing employees to electrical and fire hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 B01

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 27, 2022
Penalty
Initial $4,351 · Current $2,684 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:   Front of building: Employees were working from a scaffolding that was not fully decked, and were exposed to fall hazards.
Recent events (3)
  • — F (S) $2684
  • — C (S) $4351
  • — Z (S) $4351

1926.451 E01

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 27, 2022
Abate by
Feb 8, 2022
Penalty
Initial $4,351 · Current $2,684 Reduced
29 CFR  1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  Scaffolding front of building: Cross braces were used to access the scaffolding, exposing employees to fall hazards.
Recent events (3)
  • — F (S) $2684
  • — C (S) $4351
  • — Z (S) $4351

1926.25 A

Other-than-serious 1 instance 6 exposed
Issued
Jan 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.25(a):During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:  Southwest Corner of the building: A pile of lumber with protruding nails near the walkway, exposed employees to laceration hazards.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Jan 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   West wall: The outer insulation on the extension cord used to power the saw was pulled away from the plug exposing the inner wiring insulation. Employees were exposed to electrical and fire hazards.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View C Pacific Corporation's full OSHA safety record →