Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE COMBINATION DOOR CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE COMBINATION DOOR CO. in 1000 MORRIS STREET, FOND DU LAC, WI 54936 (NAICS 321911). OSHA activity number 345617922.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Combination Door CO. — free Get an email when a new federal OSHA severe-injury report for The Combination Door CO. is published. One employer, no account, unsubscribe in one click.
Site address
1000 MORRIS STREET
City
FOND DU LAC
State
WI
ZIP
54936
Mailing
1000 MORRIS STREET, FOND DU LAC, WI 54935
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
38
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 25, 2022
Penalty
Initial $10,151 · Current $7,106 Reduced
29 CFR  1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.   On or about October 22, 2021, at an establishment located at 1000 Morris Street in Fond du Lac, Wisconsin; employees operating the Protecto Plate Press were not protected from the pinch point created by the cylinder and the stile part resting on the backstop, exposing the employees to amputation injuries from the pinch point hazard.
Recent events (2)
  • — I (S) $7105.7
  • — Z (S) $10151

1910.305 B01 II

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Feb 25, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.  At a workplace located at 1000 Morris Street in Fond du Lac, Wisconsin:  On or about November 3, 2021, at an establishment located at 1000 Morris Street in Fond du Lac, Wisconsin; an electrical knockout was missing from the right two-hand control electrical box on the Protecto Plate Press, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5801

View The Combination Door CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345617922.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.