Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUTOMATED FRAMING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AUTOMATED FRAMING LLC in 4125 ST RD 91, OSHKOSH, WI 54904 (NAICS 238130). OSHA activity number 345629307.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Automated Framing LLC — free Get an email when a new federal OSHA severe-injury report for Automated Framing LLC is published. One employer, no account, unsubscribe in one click.
Site address
4125 ST RD 91
City
OSHKOSH
State
WI
ZIP
54904
Mailing
1812 KARAU DRIVE, MARSHFIELD, WI 54449
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
14
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Repeat Gravity 10 1 instance 6 exposed
Issued
Mar 31, 2022
Abate by
Apr 28, 2022
Penalty
Initial $12,762 · Current $3,191 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  On or about November 9, 2021, at a worksite located at 4125 State Rd 91 Oshkosh, WI, six employees were exposed to fall hazards of greater than six feet without utilizing a conventional form of fall protection.  The employees were installing floor decking on a second floor of a new two-story apartment building ten feet, four inches above surface level.  Automated Framing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.501(b)(13)), which was contained in OSHA inspection number 1479458, citation number 1, item number 3a, and was affirmed as a final order on August 19, 2020, with respect to a workplace located at 10609 Shoreview Place, Sister Bay, WI 54234.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
  • — I (R) $3190.5
  • — Z (R) $12762

View Automated Framing LLC's full OSHA safety record →