OSHA Inspection: TYK AMERICA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TYK AMERICA, INC. in 301 BRICKYARD ROAD, CLAIRTON, PA 15025 (NAICS 327120). OSHA activity number 345644256.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TYK America, INC. — free Get an email when a new federal OSHA severe-injury report for TYK America, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TYK AMERICA, INC.
Site address
301 BRICKYARD ROAD
City
CLAIRTON
State
PA
ZIP
15025
Mailing
301 BRICKYARD ROAD, CLAIRTON, PA 15025
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327120
Employees
20
Ownership type
A

11 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $10,151 · Current $5,000 Reduced
OSH ACT of 1970 Section (5)(a)(1):  Section 5(a)(1) of the Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to crushed-by, struck-by, and electrical shock hazards while using a 2 ton capacity hoist:  						 				  a) Jobsite, Lance Shed, 301 Brickyard Road, Clairton, PA 15025:  On or about November 23, 2021, repairs were not made after deficiencies were identified during periodic inspections of a Coffing brand 2 ton capacity underhung single girder hoist (serial number: EC3C-170-AYD).  The hoist continued to be used with multiple deficiencies that were noted during recent periodic inspections.  Deficiencies included, but were not limited to, a lack of warning labels, missing drop lugs on bridge, the power cord for the hoist was spliced, a missing safety latch on the hook, a cracked cover, and spliced and taped pendant cables.  Employees were exposed to crushed-by and struck-by hazards while using the Coffing hoist to lift lance pipes and molds weighing up to approximately one thousand six hundred and nineteen pounds.    Also, the damaged hoist case resulted in there being exposed electrical components which created an electrical shock hazard.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $10151

1910.147 C04 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Jobsite, Bulk Building, 301 Brickyard Road, Clairton, PA 15025:  On or about December 16, 2021, procedures were not developed for the cement mixer for the control of potentially hazardous energy when the cement mixer is cleaned after each run.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5801

1910.212 A03 II

Serious Gravity 5 4 instances 5 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $5,801 · Current $3,000 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   a) Jobsite, Bulk Building, 301 Brickyard Road, Clairton, PA 15025:  On or about November 23, 2021, the cement mixer was not provided with point of operation guarding to protect employees from the rotating blades of the mixer.   Employees operating the mixer were exposed to caught-by hazards.  b) Jobsite, brick crusher area, 301 Brickyard Road, Clairton, PA 15025:  On or about November 23, 2021, the hydraulic plunger machine used to break refractory brick into smaller pieces was not equipped with guarding to prevent employees from being struck-by pieces of brick.   Employees operating the hydraulic plunger were exposed to struck-by hazards.  c) Jobsite, Old Mil, 301 Brickyard Road, Clairton, PA 15025:   Access to the point of operation from the back side of the #3 and #4 Mitsui-Fokai brand friction presses was not guarded to prevent employees from entering the danger zone during operating cycles.  Each friction press had a capacity of 300 Tons.  d) Jobsite, New Mill, 301 Brickyard Road, Clairton, PA 15025:   Access to the point of operation from the back side of the #7 and #5 Mitsui-Fokai brand friction presses was not guarded to prevent employees from entering the danger zone during operating cycles.  Each friction press had a capacity of 300 Tons.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5801

1910.212 B

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  a) Jobsite, Old Mill, 301 Brickyard Road, Clairton, PA 15025:  On or about November 18, 2021, the legs of a brick crusher machine were not securely anchored to the floor to prevent the machine from moving during use.  The height of the machine was recently increased by the addition of metal legs which could result in the machine being less stable.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $4,351 · Current $2,000 Reduced
29 CFR  1910.219(d)(1):  Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   a)  Jobsite, Press #1 Feeder, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 23, 2021, the pulley on the feeder to press #1 was not guarded.  Employees using the feeder to press #1 were exposed to in caught-by hazards created by the lack of guarding on the pulley.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4351

1910.303 G02 I

Serious Gravity 10 2 instances 6 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $10,151 · Current $4,500 Reduced
29 CFR 1910.303(g)(2)(i):  Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures:  a) Jobsite, Mixing Area, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 18, 2021, an electrical cabinet containing high voltage (480 volt) power was left open.  Three electrical cables (one to feeder of Press 1, one to crusher machine, and one to hydraulic plunger machine) entered the cabinet.  Two of the cables entered through a cabinet door which was left open.  Employees working near the electrical cabinet were exposed to the hazards of arc flash, electrical shock and electrocution.  b) Jobsite, Mixing Area, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about December 16, 2021, a cover on an electric motor located near the steps leading to the top of the mixers was missing.  The conductors were exposed where they entered the motor.  Employees working in the area were exposed to an electrical shock hazard.  c)  Jobsite, Lance shed, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about December 16, 2021, the cover on electrical panel #2 was missing a cover.  The panel housed six switches and was located to the left of the entrance door.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $10151

1910.303 B02

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   a) Jobsite, Mixing Area, Upper Floor, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about December 16, 2021, an electrical outlet box (110 volt) being used to supply power to a pump on a barrel labeled Plenco 14045 was being used as a pendant style device.  The outlet box lacked proper strain relief and was equipped with knockouts.  The knockouts could be displaced by an employee's fingers during use.  Employees using the outlet box were exposed to the hazard of electrical shock.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B07

Deleted Serious Gravity 10 3 instances 6 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner:   a) Jobsite, Mixing Area, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 18, 2021, an electrical cabinet containing high voltage (480 volt) power was left open.  Three electrical cables (one for the Press 1 feeder, one for the brick crusher machine, and one for the hydraulic plunger) were connected to the inside of the cabinet.  Two of the cables prevented the cabinet door from being able to close.   The flexible cable (220 volt) leading to the brick crusher was draped over the floor and not protected from being damaged or snagged by forklifts used to remove bags from the bottom of the brick crusher.        b) Jobsite, Lance Shed, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 23, 2021, the electrical panel (220 Volt) marked '1' to the left of the Lance Shed entrance was left open and there was grey and blue duct tape over the bottom portion of the panel.    c) Jobsite, Lance Shed, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 23, 2021, the electrical panel marked '2' to the left of the Lance Shed entrance was left open (the panel cover was missing)  and there was grey duct tape covering the top portion of the panel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 C10

Willful Gravity 10 1 instance 4 exposed
Issued
Apr 27, 2022
Abate by
May 9, 2022
Penalty
Initial $72,514 · Current $40,000 Reduced
1910.333(c)(10)  "Interlocks." Only a qualified person following the requirements of paragraph (c) of this section may defeat an electrical safety interlock, and then only temporarily while he or she is working on the equipment. The interlock system shall be returned to its operable condition when this work is completed. [55 FR 32016, Aug. 6, 1990; 55 FR 42053, Nov. 1, 1990; as amended at 59 FR 4476, Jan. 31, 1994] 29 CFR  1910.212(a)(3)(ii):  Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   a) Jobsite, Old Mill, 301 Brickyard Road, Clairton, PA 15025:  On or about November 18, 2021, one or more methods of machine guarding was not provided to protect employees from the rotating rollers of the brick crushing machine.  A safety switch on lid of the brick crusher was bypassed which permitted the crusher to run with the lid open.  Employees using the crusher to grind up bad bricks were exposed to caught-by hazards.
Recent events (2)
  • — I (W) $40000
  • — Z (W) $72514

1910.303 E01 II

Other-than-serious 3 instances 7 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(e)(1)(ii):  Electric equipment was used without markings giving voltage, current, wattage, or other ratings as necessary:   a) Jobsite, Mixing Area, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 18, 2021, an electrical cabinet containing high voltage (480 volt) power was not equipped with marking giving the voltage, current, wattage, and other ratings necessary.  The cabinet was used to supply power to the Press 1 feeder, the brick crusher machine, and the hydraulic plunger.  b) Jobsite, behind brick crusher machine, Old Mill, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 18, 2021, electrical panels marked '1', '2' and '3' were not equipped with markings giving voltage, current, wattage, or other ratings as necessary.    c) Jobsite, Maintenance shop area, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about December 16, 2021, an electrical panel marked '2' was not equipped with markings giving voltage, current, wattage, or other ratings as necessary.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 4 instances 6 exposed
Issued
Apr 27, 2022
Abate by
May 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   a) Behind brick crusher machine, Old Mill, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 18, 2021, a hydraulic plunger machine was stored directly in front of an electrical panel marked with '3.'  The plunger machine was located between the brick crusher machine and the wall.     b) Maintenance Shop, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about December 16, 2021, two pieces of equipment (one blue and one silver) manufactured by Applied Test Systems Inc. were installed directly in front of an electrical panel marked '2'.  c) Maintenance Shop, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about December 16, 2021, light bulb boxes, containers and other materials were stored directly in front of multiple electrical switches including those marked '1', '2', '5', 6', '8', and '9'.  d) Lance Shed, 301 Brickyard Road, Clairton, PA 15025:  Observed on or about November 23, 2021, an orange flexible cord was stored on the panel door of an electrical panel marked '1'.  The orange cord was draped over the electrical panel door.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View TYK America, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345644256.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.