OSHA Inspection: COMFORT COOLING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMFORT COOLING, INC. in 7AA PETER'S REST, CHRISTIANSTED, VI 00820 (NAICS 238220). OSHA activity number 345653505.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Comfort Cooling, INC. — free Get an email when a new federal OSHA severe-injury report for Comfort Cooling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7AA PETER'S REST
City
CHRISTIANSTED
State
VI
ZIP
00820
Mailing
P.O. BOX 993, CHRISTIANSTED, VI 00821
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
17
Ownership type
A

3 citations on file for this inspection.

1910.28 B01 I

Other-than-serious 2 instances 4 exposed
Issued
Apr 21, 2022
Abate by
May 6, 2022
Penalty
Initial $465 · Current $465
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  a. On or about November 18, 2021, at the warehouse southeast corner storage loft, employees were exposed to falls from a working/walking surface with an unprotected side or edge that was 8 feet (2.44 m) above a hard concrete lower level.  b. On or about November 18, 2021, at the warehouse storage loft on top of the administration office, employees were exposed to falls from a working/walking surface with an unprotected side or edge that was 8 feet (2.44 m) above a hard concrete lower level.  NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (O) $465
  • — Z (O) $465

1910.28 B11 II

Other-than-serious 2 instances 4 exposed
Issued
Apr 21, 2022
Abate by
May 6, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with a stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements.   a. On or about November 18, 2021, at the warehouse, the employer did not ensure that the stairs connecting the ground level to the southeast corner storage loft, having 12 risers, were equipped with a stair rail system on each open side, as described in 29 CFR 1910.28 Table D-2 - Stairway Handrail Requirements.  b. On or about November 18, 2021, at the warehouse, the employer did not ensure that the stairs connecting the ground level and the storage loft on top of the administration office, having 13 risers, were equipped with a stair rail system with handrail on the open side, as described in 29 CFR 1910.28 Table D-2 - Stairway Handrail Requirements.  NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 4 exposed
Issued
Apr 21, 2022
Abate by
May 6, 2022
Penalty
Initial $465 · Current $465
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  a. On or about November 18, 2021, at the sheet metal shop; the electrical service panel in the area was not readily accessible. Access to the electrical service panel was obstructed by several sheet metal panels, of different shapes and sizes, stored in the floor below and in front.  NOTE:  Certification of abatement is not required for this citation item since it was submitted prior to citation issuance.