OSHA Inspection: FENNER DUNLOP TOLEDO, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FENNER DUNLOP TOLEDO, LLC in 146 S. WESTWOOD AVE., TOLEDO, OH 43607 (NAICS 333922). OSHA activity number 345654016.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fenner Dunlop Toledo, LLC — free Get an email when a new federal OSHA severe-injury report for Fenner Dunlop Toledo, LLC is published. One employer, no account, unsubscribe in one click.
Site address
146 S. WESTWOOD AVE.
City
TOLEDO
State
OH
ZIP
43607
Mailing
146 S. WESTWOOD AVE., TOLEDO, OH 43607
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333922
Employees
40
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 25, 2022
Abate by
Jul 20, 2023
Penalty
Initial $11,747 · Current $5,874 Reduced
29 CFR  1910.147(c)(7)(i):The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  On or about November 18, 2021, employees at Fenner Dunlop Toledo, LLC were exposed to point of operation in-going nip point hazards and crushing injury, in that they were performing Lockout/Tagout twice daily and were not properly trained on the Lockout/Tagout procedures of the employers Farrell Shaw calender (Unit #522). The employer did not ensure employees were trained in the purpose and function of the energy control program, with regards to the mechanical, electrical, and pneumatic energy sources within the Farrell Shaw calender, during machine set up process, maintenance and repair.
Recent events (3)
  • — P (S) $5874
  • — I (S) $5874
  • — Z (S) $11747

1910.147 D

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 25, 2022
Abate by
Jul 20, 2023
Penalty
Initial $11,747 · Current $0 Reduced
29 CFR  1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about November 18, 2021, employees at Fenner Dunlop Toledo, LLC were exposed to in-going nip point hazards and crushing injury, in that the Farrell Shaw calender (Unit #522) was not locked out prior to employees placing any part of his or her body where an in-going nip point exists during the energized calender's set up cycle. The employer did not ensure that energy control application steps to control the mechanical, electrical, and pneumatic energy sources were implemented prior to servicing tasks - the employer did not: 	Ensure that equipment was turned off or shut down. 	Physically operate energy isolating devices to control energy sources and affix lockout device(s). 	Ensure that all potentially hazardous stored or residual energy was relieved, disconnected, and rendered safe. 	Verify that isolation and deenergization of the machine or equipment had been accomplished.
Recent events (3)
  • — P (S) $0
  • — I (S) $0
  • — Z (S) $11747

View Fenner Dunlop Toledo, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345654016.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.