Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TROJAN BATTERY COMPANY, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TROJAN BATTERY COMPANY, LLC in 3012 GEORGE LYONS PARKWAY, SANDERSVILLE, GA 31082 (NAICS 335912). OSHA activity number 345714000.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trojan Battery Company, LLC — free Get an email when a new federal OSHA severe-injury report for Trojan Battery Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3012 GEORGE LYONS PARKWAY
City
SANDERSVILLE
State
GA
ZIP
31082
Mailing
3012 GEORGE LYONS PARKWAY, SANDERSVILLE, GA 31082
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335912
Employees
200
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 8, 2022
Abate by
May 25, 2022
Penalty
Initial $8,806 · Current $6,164 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   a. On or about December 28, 2021, at Post Burn/Leak Test Conveyor Area, employer did not ensure that the procedure was utilized for the control of potentially hazardous energy, for employees who were performing operations on equipment such as but not limited to, servicing, maintaining and/or repairing the post burn/leak test, a section of the moving/energized conveyor.
Recent events (2)
  • — I (S) $6164.2
  • — Z (S) $8806

1910.147 D03

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 8, 2022
Abate by
May 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    a. On or about December 28, 2021, at Post Burn/Leak Test Conveyor Area, employees were exposed to caught-between hazard. The employer did not ensure that the disconnect means to the conveyor system was easily accessible, in the event that maintenance employees need to lockout sections of the conveyor for maintenance and/or repair.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 8, 2022
Abate by
May 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a. On or about December 28, 2021, at Post Burn/Leak Test Conveyor Area, employer did not ensure that the locking out/tagging out of the device was utilized for the control of potentially hazardous energy, for employees who were performing operations on equipment such as but not limited to, servicing, maintaining and/or repairing the post burn/leak test, a section of the moving/energized conveyor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Trojan Battery Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345714000.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.