Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAVFAC MID-ATLANTIC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NAVFAC MID-ATLANTIC in NAVAL MEDICAL CENTER PORTSMOUTH 620 JOHN PAUL JONES CIRCLE, PORTSMOUTH, VA 23708 (NAICS 561210). OSHA activity number 345758445.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Navfac Mid-Atlantic — free Get an email when a new federal OSHA severe-injury report for Navfac Mid-Atlantic is published. One employer, no account, unsubscribe in one click.
Establishment
NAVFAC MID-ATLANTIC
Site address
NAVAL MEDICAL CENTER PORTSMOUTH 620 JOHN PAUL JONES CIRCLE
City
PORTSMOUTH
State
VA
ZIP
23708
Mailing
9324 VIRGINIA AVE., NORFOLK, VA 23511
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
7000
Ownership type
D

7 citations on file for this inspection.

1904.40 A

Other-than-serious 1 instance 1 exposed
Issued
Mar 7, 2022
Abate by
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): The employer did not provide an authorized government representative the 1904 records within the four business hours:  On or about 02-01-2022 and times prior thereto, located at NAVFAC Mid-Atlantic NSA Hampton Roads - NMCP, Building 273, Portsmouth, VA 23702:   The OSHA 300 Logs and 300A Summary, or equivalent forms, were requested in-person during the Opening Conference on February 01st, 2022 at 10:30 AM and they were provided to the authorized government representative on February 01st, 2022 at 9:47 PM.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
  • — Z (O) $0

1910.23 B08

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 7, 2022
Abate by
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.23(b)(8): The employer did not ensure that ladders are used only for the purposes for which they were designed.  On or about 09-21-2021 to 09-27-22021, and times prior thereto, located at NAVFAC Mid-Atlantic NSA Hampton Roads - Naval Medical Center Portsmouth, Portsmouth, VA 23702 on the 15th floor, HVAC Chiller rooftop area:  Employee(s) were exposed to a fall hazard in excess of 14 feet after climbing and using a fly section of an extension ladder.  The fly section had been previously removed from the base section and was being used as a single straight ladder and not as designed.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.23 B10

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 7, 2022
Abate by
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.23(b)(10): The employer did not ensure that any ladder with structural or other defects was immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with � 1910.145 and removed from service until repaired in accordance with � 1910.22(d), or replaced.  On or about 09-21-2021 to 09-27-22021, and times prior thereto, located at NAVFAC Mid-Atlantic NSA Hampton Roads - Naval Medical Center Portsmouth, Portsmouth, VA 23702 on the 15th floor, HVAC Chiller rooftop area:  Employee(s) were exposed to a fall hazard in excess of 14 feet after climbing and using a fly section of an extension ladder that had rubber tread riveted on the "foot" area, whereas the rubber tread had separated and was not secured to the ladder.  This rubber tread addition was not original manufactured design.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.23 C11

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 7, 2022
Abate by
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface.  On or about 09-21-2021 to 09-27-22021, and times prior thereto, located at NAVFAC Mid-Atlantic NSA Hampton Roads - Naval Medical Center Portsmouth, Portsmouth, VA 23702 on the 15th floor, HVAC Chiller rooftop area:  Employee(s) were exposed to a fall hazard in excess of 14 feet after climbing and using a fly section of an extension ladder that did not extend 3 feet above the landing surface.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.28 B01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 7, 2022
Abate by
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  On or about 09-21-2021 to 09-27-22021, and times prior thereto, located at NAVFAC Mid-Atlantic NSA Hampton Roads - Naval Medical Center Portsmouth, Portsmouth, VA 23702 on the 15th floor, HVAC Chiller rooftop area:  Employee(s) were exposed to a fall hazard in excess of 14 feet on one side and 15 stories high on the other while standing on a ledge just inside of the buildings parapet wall while changing aircraft warning fixture lightbulbs without an adequate form of fall protection.  The parapet wall was estimated to be less than 36 inches in height.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.30 A03 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 7, 2022
Abate by
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.30(a)(3)(iv): The employer did not train each employee in the correct use of personal fall protection systems and equipment specified in paragraph (a)(1) of this section, including, but not limited to, proper hook-up, anchoring, and tie-off techniques, and methods of equipment inspection and storage, as specified by the manufacturer.  On or about 09-21-2021 to 09-27-22021, and times prior thereto, located at NAVFAC Mid-Atlantic NSA Hampton Roads - Naval Medical Center Portsmouth, Portsmouth, VA 23702 on the 15th floor, HVAC Chiller rooftop area:  Employee(s) were exposed to a fall hazard in excess of 14 feet while changing aircraft warning fixture lightbulbs without an adequate form of fall protection.  The parapet wall was estimated to be less than 36 inches in height.  The employee used a lightening grounding cable that was bolted to the top concrete cap of the parapet wall as a fall protection anchor point.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.140 C13 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 7, 2022
Abate by
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.140(c)(13)(i): Anchorages were not capable of supporting at least 5000 pounds (22.2 kN) for each employee attached.  On or about 09-21-2021 to 09-27-22021, and times prior thereto, located at NAVFAC Mid-Atlantic NSA Hampton Roads - Naval Medical Center Portsmouth, Portsmouth, VA 23702 on the 15th floor, HVAC Chiller rooftop area:  Employee(s) were exposed to a fall hazard in excess of 14 feet while changing aircraft warning fixture lightbulbs without an adequate form of fall protection.  Employee used a lightening grounding cable that was bolted to the top concrete cap of the parapet wall as an anchor point that was not a certified anchor point to support at least 5000 pounds for each employee attached.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

View Navfac Mid-Atlantic's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345758445.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.