Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL DOORS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GENERAL DOORS CORPORATION in 1 MONROE STREET, BRISTOL, PA 19007 (NAICS 332321). OSHA activity number 345774640.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Doors Corporation — free Get an email when a new federal OSHA severe-injury report for General Doors Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1 MONROE STREET
City
BRISTOL
State
PA
ZIP
19007
Mailing
P O BOX 205, BRISTOL, PA 19007
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
41
Ownership type
A

4 citations on file for this inspection.

1910.213 R04

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 26, 2022
Penalty
Initial $4,351 · Current $3,500 Reduced
29 CFR  1910.213(r)(4): Suitable guard(s) and exhaust hood(s) were not provided to reduce to a minimum the hazard due to the point of operation of the door beveling machine:   a)Warehouse Floor- On or about February 10, 2022, the Celaschi horizontal cutting blade was not provided with a guard at the point of operation.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4351

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 26, 2022
Penalty
Initial $3,263 · Current $2,000 Reduced
29 CFR  1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)Warehouse Floor- On or about February 10, 2022, employees working in the wood working portion of the facility were exposed to compressed air that was measured to be above 95 PSI while they were cleaning excess saw dust off of a work surface.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3263

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 26, 2022
Penalty
Initial $4,351 · Current $3,500 Reduced
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Warehouse Floor- On or about February 10, 2022, sufficient access and working space was not maintained due to materials being stored within 3 feet of electrical panel(s).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4351

1910.253 B04 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 26, 2022
Penalty
Initial $3,263 · Current $2,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour.  a) Warehouse Floor- On or about February 10, 2022, employees were exposed to fire hazards in that oxygen and acetylene tanks were not stored a minimum distance of 20 feet apart.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3263

View General Doors Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345774640.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.