Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ULINE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ULINE, INC. in 700 ULINE WAY, ALLENTOWN, PA 18106 (NAICS 424130). OSHA activity number 345780522.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Uline, INC. — free Get an email when a new federal OSHA severe-injury report for Uline, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ULINE, INC.
Site address
700 ULINE WAY
City
ALLENTOWN
State
PA
ZIP
18106
Mailing
12575 ULINE DRIVE, PLEASANT PRAIRIE, WI 53158
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424130
Employees
850
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2022
Abate by
Apr 29, 2022
Penalty
Initial $14,502 · Current $10,500 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) 700 Uline Way Allentown, PA 18106: On or about February 08, 2022, the employer did not ensure that inspections of the energy control procedure for the Q1000 pallet stretch wrapper were conducted at least annually.
Recent events (2)
  • — I (O) $10500
  • — Z (S) $14502

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 19, 2022
Abate by
Apr 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) 700 Uline Way Allentown, PA 18106: On or about February 08, 2022, an employee was exposed to machine hazards associated with moving parts and in-running nip points from the movement of the Q1000 pallet stretch wrapper conveyor when clearing excess plastic bags from the line. The equipment was not stopped and locked out before work was performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Uline, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345780522.