JAMESTOWN, NY —
OSHA Inspection: THE RESOURCE CENTER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE RESOURCE CENTER in 75 JONES AND GIFFORD AVE, JAMESTOWN, NY 14701 (NAICS 314910). OSHA activity number 345780779.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE RESOURCE CENTER
- Site address
- 75 JONES AND GIFFORD AVE
- City
- JAMESTOWN
- State
- NY
- ZIP
- 14701
- Mailing
- 75 JONES AND GIFFORD AVE, JAMESTOWN, NY 14701
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314910
- Employees
- 160
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 24, 2022
- Abate by
- Apr 8, 2022
- Penalty
- Initial $9,324 · Current $6,993 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by puncture points: a) On or about 02/10/2022 - 4th floor Allied building; where the pedal, for stroke initiation, on three cap and socket machines was not guarded to prevent an unintended cycle of the machine. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $6993
- — Z (S) $9324
1910.303 B02
- Issued
- Feb 24, 2022
- Abate by
- Mar 18, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 02/22/2022 - 4th floor Allied building; where a metal, single gang receptacle box (approved for "mounted in place" applications) was used at the end of a pendant to supply power to a cap and socket machine. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at The Resource Center
View The Resource Center's full OSHA safety record →
More inspections in this industry (NAICS 314910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345780779.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.