HAINES CITY, FL —
OSHA Inspection: SOFIDEL AMERICA CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SOFIDEL AMERICA CORP. in 1006 MARLEY DR., HAINES CITY, FL 33844 (NAICS 322121). OSHA activity number 345787220.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOFIDEL AMERICA CORP.
- Site address
- 1006 MARLEY DR.
- City
- HAINES CITY
- State
- FL
- ZIP
- 33844
- Mailing
- 1006 MARLEY DR, HAINES CITY, FL 33844
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322121
- Employees
- 200
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D04 I
- Issued
- Aug 4, 2022
- Abate by
- Aug 30, 2022
- Penalty
- Initial $8,287 · Current $8,287
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a. On or about 02/09/2022, at the RO-2 embosser machine - employees were exposed to caught-in hazards while using their hands to thread 2-ply paper through embosser section machine rollers, in that, lockout and tagout devices were not utilized.
Recent events (2)
- — I (O) $8287
- — Z (S) $8287
1910.147 C07 I A
- Issued
- Aug 4, 2022
- Abate by
- Aug 30, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a. On or about 02/09/2022, at the RO-2 embosser machine - the employer did not ensure each lockout/tagout authorized employees were trained.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Sofidel America Corp.
View Sofidel America Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 322121)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345787220.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.