Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RMP HOME IMPROVEMENT EXPERTS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RMP HOME IMPROVEMENT EXPERTS LLC in 15 MALLOWHILL RD, SPRINGFIELD, MA 01129 (NAICS 238160). OSHA activity number 345788822.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RMP Home Improvement Experts LLC — free Get an email when a new federal OSHA severe-injury report for RMP Home Improvement Experts LLC is published. One employer, no account, unsubscribe in one click.
Site address
15 MALLOWHILL RD
City
SPRINGFIELD
State
MA
ZIP
01129
Mailing
190 BEEMIS AVE 2ND FLOOR, CHICOPEE, MA 01020
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
May 6, 2022
Penalty
Initial $3,108 · Current $1,119 Reduced
29 CFR  1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access:  15 Mallowhill Rd., Springfield, MA: On or about February 17, 2022, an employee performing  roofing work was observed climbing an aluminum extension ladder that  the employer did not ensure was positioned so that the ladder extended 3 feet past the upper landing surface (roof).   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19 (d) (1).
Recent events (2)
  • — I (S) $1118.7
  • — Z (S) $3108

1926.1053 B05 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 6, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(5)(i):Non-self-supporting ladders were used at an angle such that the horizontal distance from the top support to the foot of the ladder was  greater than one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):  15 Mallowhill Rd., Springfield, MA: On or about February 17, 2022, the employer had not ensured that an employee using  a portable extension ladder to access an upper level was installed in manner in which the working angle did not exceed a ratio of 4:1 or one quarter the working length of the ladder. The ladder was set up at a 2.6:4 angle exposing employees to ladder displacement and fall from height hazards.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19 (d) (1).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B12

Serious Gravity 5 1 instance 1 exposed
Issued
May 6, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(12):Ladders did not have nonconductive siderails when they were used where the employee or the ladder could contact exposed energized electrical equipment:  15 Mallowhill Rd., Springfield, MA: On or about February 17, 2022, an employee was observed climbing on an aluminum ladder which the employer allowed to be set less that 7 feet from the live, uninsulated house electrical service drop entrance cable.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19 (d) (1).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
May 6, 2022
Penalty
Initial $8,701 · Current $2,238 Reduced
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:  15 Mallowhill Rd., Springfield, MA: On or about February 17, 2022, an employee was observed working on a residential structure engaged in roofing activities (caulking chimney) with unprotected sides and edges greater than 10 feet above the  ground and was not protected by either guard rails, safety net systems or personal fall arrest systems exposing him to fall hazards.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19 (d)(1).  RMP Home Improvement Experts, LLC was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.501 (b)13, which was contained in OSHA inspection number 1519043 , citation number 1, item number 1 and was affirmed as a final order on 10/22/2021, with respect to a workplace located at  86-88 Jasper St., Springfield, MA.
Recent events (2)
  • — I (R) $2237.7
  • — Z (R) $8701

View RMP Home Improvement Experts LLC's full OSHA safety record →