HOUSTON, TX —
OSHA Inspection: NCI GROUP, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of NCI GROUP, INC. in 7301 FAIRVIEW ST., HOUSTON, TX 77041 (NAICS 332311). OSHA activity number 345790836.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NCI GROUP, INC.
- Site address
- 7301 FAIRVIEW ST.
- City
- HOUSTON
- State
- TX
- ZIP
- 77041
- Mailing
- 7301 FAIRVIEW ST., HOUSTON, TX 77041
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332311
- Employees
- 229
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C05 II D
- Issued
- Aug 1, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $11,396 · Current $7,977 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): On or about February 17, 2022: a. In the Trim area, where an employee was exposed to a struck-by hazard when performing service and maintenance to the Slitter without indicating the identity of the employee that applied the device. b. In the Rods Department, where an employee was exposed to a struck-by hazard when performing service to the Threader machine without indicating the identity of the employee that applied the device.
Recent events (2)
- — I (S) $7977.2
- — Z (S) $11396
1910.147 F03 II D
- Issued
- Aug 1, 2022
- Abate by
- Aug 5, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D):Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: On or about February 17, 2022, in the Trim area, where an employee was exposed to a struck-by hazard when performing service and maintenance to the Slitter without each employee having affixed a personal lockout device to a group lockout device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Aug 1, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $14,502 · Current $10,151 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about February 22, 2022, in the Structural West area, where an employee was operating the Controlled Automation angle cutter without the unit being guarded. b. On or about February 22, 2022, in the Structural West area, where an employee was operating the bar line cutter without the unit being guarded. c. On or about February 22, 2022, in the Structural West area, where an employee was operating the Controlled Automation angle cutter without the unit being guarded. d. On or about May 16, 2022, in the Structural West area, where an employee was operating the Vertical Band Saw without the unit being guarded.
Recent events (2)
- — I (S) $10151.4
- — Z (S) $14502
1910.212 A03 II
- Issued
- Aug 1, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about February 17, 2022, in the trim area, where an employee was exposed to a struck-by hazard when operating the Betenbender Hydraulic Press Brake without a point of operation guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 I
- Issued
- Aug 1, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $11,396 · Current $7,977 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i):Unused openings in boxes, raceways, auxillary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substanially equivalent to the wall of the equipment: On or about February 17, 2022, in the Trim area, where an employee was exposed to an electrical hazard when accessing a switch box that had an unused opening.
Recent events (2)
- — I (S) $7977.2
- — Z (S) $11396
1910.147 C04 I
- Issued
- Aug 1, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $56,980 · Current $14,502 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 17, 2022,and at times prior thereto, in the Structural East area, where an employee was exposed to a struck-by hazard when performing service and maintenance to the Beam Line machinery without the employer having developed energy isolation procedures. NCI Group, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii) , which was contained in OSHA inspection number 1261237, citation number 1, item number 1a and was affirmed as a final order on November 21, 2017, with respect to a workplace located at 1150 Marietta Industrial Dr., Marietta, GA 30062.
Recent events (2)
- — I (S) $14502
- — Z (R) $56980
1910.134 H02 I
- Issued
- Aug 1, 2022
- Abate by
- Aug 5, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i):Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: On or about February 17, 2022, in the Structural East Area, where an employee was exposed to a respiratory hazard without storing their respirator to protect it from contamination and dust.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at NCI Group, INC.
View NCI Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332311)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345790836.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.