Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NCI GROUP, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of NCI GROUP, INC. in 7301 FAIRVIEW ST., HOUSTON, TX 77041 (NAICS 332311). OSHA activity number 345790836.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NCI Group, INC. — free Get an email when a new federal OSHA severe-injury report for NCI Group, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NCI GROUP, INC.
Site address
7301 FAIRVIEW ST.
City
HOUSTON
State
TX
ZIP
77041
Mailing
7301 FAIRVIEW ST., HOUSTON, TX 77041
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
229
Ownership type
A

7 citations on file for this inspection.

1910.147 C05 II D

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 1, 2022
Abate by
Aug 11, 2022
Penalty
Initial $11,396 · Current $7,977 Reduced
29 CFR  1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  On or about February 17, 2022:  a.  In the Trim area, where an employee was exposed to a struck-by hazard when performing service and maintenance to the Slitter without indicating the identity of the employee that applied the device.   b.  In the Rods Department, where an employee was exposed to a struck-by hazard when performing service to the Threader machine without indicating the identity of the employee that applied the device.
Recent events (2)
  • — I (S) $7977.2
  • — Z (S) $11396

1910.147 F03 II D

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2022
Abate by
Aug 5, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(3)(ii)(D):Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:  On or about February 17, 2022, in the Trim area, where an employee was exposed to a struck-by hazard when performing service and maintenance to the Slitter without each employee having affixed a personal lockout device to a group lockout device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 4 instances 5 exposed
Issued
Aug 1, 2022
Abate by
Aug 11, 2022
Penalty
Initial $14,502 · Current $10,151 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a.  On or about February 22, 2022, in the Structural West area, where an employee was operating the Controlled Automation angle cutter without the unit being guarded.  b.  On or about February 22, 2022, in the Structural West area, where an employee was operating the bar line cutter without the unit being guarded.  c. On or about February 22, 2022, in the Structural West area, where an employee was operating the Controlled Automation angle cutter without the unit being guarded.  d. On or about May 16, 2022, in the Structural West area, where an employee was operating the Vertical Band Saw without the unit being guarded.
Recent events (2)
  • — I (S) $10151.4
  • — Z (S) $14502

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 1, 2022
Abate by
Aug 11, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  On or about February 17, 2022, in the trim area, where an employee was exposed to a struck-by hazard when operating the Betenbender Hydraulic Press Brake without a point of operation guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2022
Abate by
Aug 11, 2022
Penalty
Initial $11,396 · Current $7,977 Reduced
29 CFR  1910.303(b)(7)(i):Unused openings in boxes, raceways, auxillary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substanially equivalent to the wall of the equipment:  On or about February 17, 2022, in the Trim area, where an employee was exposed to an electrical hazard when accessing a switch box that had an unused opening.
Recent events (2)
  • — I (S) $7977.2
  • — Z (S) $11396

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2022
Abate by
Aug 11, 2022
Penalty
Initial $56,980 · Current $14,502 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about February 17, 2022,and at times prior thereto, in the Structural East area, where an employee was exposed to a struck-by hazard when performing service and maintenance to the Beam Line machinery without the employer having developed energy isolation procedures.     NCI Group, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii) , which was contained in OSHA inspection number 1261237, citation number 1, item number 1a and was affirmed as a final order on November 21, 2017, with respect to a workplace located at 1150 Marietta Industrial Dr., Marietta, GA 30062.
Recent events (2)
  • — I (S) $14502
  • — Z (R) $56980

1910.134 H02 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 1, 2022
Abate by
Aug 5, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(h)(2)(i):Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  On or about February 17, 2022, in the Structural East Area, where an employee was exposed to a respiratory hazard without storing their respirator to protect it from contamination and dust.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NCI Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345790836.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.